3D printing based on imaging data: review of medical applications

F Rengier, A Mehndiratta, H Von Tengg-Kobligk… - International journal of …, 2010 - Springer
Purpose Generation of graspable three-dimensional objects applied for surgical planning,
prosthetics and related applications using 3D printing or rapid prototyping is summarized …

Three-dimensional printing: basic principles and applications in medicine and radiology

GB Kim, S Lee, H Kim, DH Yang… - Korean journal of …, 2016 - synapse.koreamed.org
The advent of three-dimensional printing (3DP) technology has enabled the creation of a
tangible and complex 3D object that goes beyond a simple 3D-shaded visualization on a flat …

A review of micromodels and their use in two‐phase flow studies

NK Karadimitriou, SM Hassanizadeh - Vadose Zone Journal, 2012 - Wiley Online Library
During the last 25 to 30 yr, micromodels have been increasingly used to study the behavior
of fluids inside microstructures in various research areas. Studies have included chemical …

A systematic review of image segmentation methodology, used in the additive manufacture of patient-specific 3D printed models of the cardiovascular system

N Byrne, M Velasco Forte, A Tandon… - JRSM …, 2016 - journals.sagepub.com
Background Shortcomings in existing methods of image segmentation preclude the
widespread adoption of patient-specific 3D printing as a routine decision-making tool in the …

Biomaterials and 3D printing techniques used in the medical field

A Mishra, V Srivastava - Journal of Medical Engineering & …, 2021 - Taylor & Francis
An implants' effectiveness depends upon the form of biomaterial used in its manufacture. A
suitable material for implants should be biocompatible, sterile, mechanically stable and …

High-resolution fluid–structure interaction simulations of flow through a bi-leaflet mechanical heart valve in an anatomic aorta

I Borazjani, L Ge, F Sotiropoulos - Annals of biomedical engineering, 2010 - Springer
We have performed high-resolution fluid–structure interaction simulations of physiologic
pulsatile flow through a bi-leaflet mechanical heart valve (BMHV) in an anatomically realistic …

[HTML][HTML] Fontan hemodynamics: importance of pulmonary artery diameter

LP Dasi, R KrishnankuttyRema, HD Kitajima… - The Journal of thoracic …, 2009 - Elsevier
OBJECTIVE: We quantify the geometric and hemodynamic characteristics of extracardiac
and lateral tunnel Fontan surgical options and correlate certain anatomic characteristics with …

[HTML][HTML] Uso y aplicación de la tecnología de impresión y bioimpresión 3D en medicina

ÁA César-Juárez, A Olivos-Meza… - Revista de la Facultad …, 2018 - scielo.org.mx
En el mundo actual, las llamadas “tecnologías de fabricación por adición” o impresión 3D
también llamado prototipado rápido, han trascendido las fronteras de casi todos los campos …

Introduction of a new optimized total cavopulmonary connection

DD Soerensen, K Pekkan, D de Zélicourt… - The Annals of thoracic …, 2007 - Elsevier
BACKGROUND: Several variations of the total cavopulmonary connection (TCPC) have
been investigated for favorable fluid mechanics and flow distribution. This study presents a …

Use of rapid prototyping models in the planning of percutaneous pulmonary valved stent implantation

A Armillotta, P Bonhoeffer, G Dubini… - Proceedings of the …, 2007 - journals.sagepub.com
Percutaneous replacement of the pulmonary valve is a recently developed inter-ventional
technique which involves the implantation of a valved stent in the pulmonary trunk. It relies …