Strengthening of Confined Masonry Walls Using Reinforced Cementitious Matrix Subjected to In-Plane Loads: A State-of-The-Art Review
Confined masonry (CM) buildings experienced some major damages in past earthquakes.
Numerous studies have investigated various strengthening techniques to improve the …
Numerous studies have investigated various strengthening techniques to improve the …
[HTML][HTML] Cyclic shear-compression testing of brick masonry walls repaired and retrofitted with basalt textile reinforced mortar
This paper reports an experimental programme on masonry walls composed of handmade
solid clay brick and hydraulic lime mortar. Reversed cyclic shear compression tests were …
solid clay brick and hydraulic lime mortar. Reversed cyclic shear compression tests were …
In-plane shear behaviour by diagonal compression testing of brick masonry walls strengthened with basalt and steel textile reinforced mortars
This paper presents an experimental study of the structural behaviour of masonry walls
retrofitted with Textile Reinforced Mortar (TRM) to improve their in-plane shear strength and …
retrofitted with Textile Reinforced Mortar (TRM) to improve their in-plane shear strength and …
[HTML][HTML] Masonry walls strengthened with Textile Reinforced Mortars (TRM) and subjected to in-plane cyclic loads after real fire exposure
L Estevan, B Torres, FJ Baeza, FB Varona… - Engineering Structures, 2023 - Elsevier
A key feature that determines the seismic performance of masonry buildings is the ability of
the walls to withstand in-plane cyclic loads. In this context, Textile Reinforced Mortars (TRM) …
the walls to withstand in-plane cyclic loads. In this context, Textile Reinforced Mortars (TRM) …
Cyclic in-plane behavior of unreinforced and confined masonry walls retrofitted by shotcrete: Experimental investigation
SRS Rezaee, M Soltani, M Nikooravesh - Engineering Structures, 2022 - Elsevier
This study aimed to investigate the efficiency of shotcrete retrofitting method for seismic
rehabilitation of conventional unreinforced and confined masonry walls. In this regard, six …
rehabilitation of conventional unreinforced and confined masonry walls. In this regard, six …
Seismic retrofit of unreinforced masonry walls using precast panels of fiber-reinforced cementitious composite
SH Park, NH Dinh, SH Kim, JW Hwang… - Journal of Building …, 2022 - Elsevier
In this study, a practical seismic retrofit technique was developed for unreinforced masonry
(URM) walls using precast panels of fiber-reinforced cementitious composites (FRCC). A …
(URM) walls using precast panels of fiber-reinforced cementitious composites (FRCC). A …
[HTML][HTML] Experimental study of fibre-reinforced TRC shear strengthening applications on non-stirrup reinforced concrete T-beams
Abstract Textile Reinforced Concrete (TRC) materials have proven to be not only a viable
solution, but also an effective one when used to strengthen Reinforced Concrete (RC) …
solution, but also an effective one when used to strengthen Reinforced Concrete (RC) …
Building constructions characteristics and mechanical properties of confined masonry walls in San Miguel (Puno-Peru)
N Tarque, E Pancca-Calsin - Journal of Building Engineering, 2022 - Elsevier
House self-construction and self-management are very common in different cities in Peru,
which is the case in several areas in the district of San Miguel (Puno). This is due to the lack …
which is the case in several areas in the district of San Miguel (Puno). This is due to the lack …
[HTML][HTML] Experimental cyclic behaviour of shear masonry walls reinforced with single and double layered Steel Reinforced Grout
Recent research on the mechanical characterisation of Steel Reinforced Grout (SRG) has
highlighted its excellent performance as strengthening solutions for masonry structures …
highlighted its excellent performance as strengthening solutions for masonry structures …
Experimental in-plane behaviour and drift-based fragility assessment of typical Peruvian confined masonry walls
Around 56% of dwellings in Lima are constructed with confined masonry walls, and over
70% are built without engineering design and supervision. This building stock is exposed to …
70% are built without engineering design and supervision. This building stock is exposed to …