A quarter‐century of metrology using synchrotron radiation by PTB in Berlin

B Beckhoff, A Gottwald, R Klein… - … status solidi (b), 2009 - Wiley Online Library
For more than 25 years, the Physikalisch‐Technische Bundesanstalt has been strongly
engaged in the field of metrology using synchrotron radiation. In Berlin, this research …

The Avogadro constant determination via enriched silicon-28

P Becker, H Friedrich, K Fujii, W Giardini… - Measurement …, 2009 - iopscience.iop.org
This review describes the efforts of several national metrology institutes to replace the
present definition of the kilogram by a new one based on the mass of a given number of 12 …

BAMline: the first hard X-ray beamline at BESSY II

W Görner, MP Hentschel, BR Müller… - Nuclear Instruments and …, 2001 - Elsevier
The first hard X-ray beamline at BESSY II will be installed by BAM and PTB at a
superconducting 7T wavelength shifter. The main optical elements of the beamline are a …

Layout and first XRF applications of the BAMline at BESSY II

H Riesemeier, K Ecker, W Görner… - X‐Ray Spectrometry …, 2005 - Wiley Online Library
The first hard x‐ray beamline at BESSY II has been installed by BAM and PTB at a
superconducting 7 T wavelength shifter. The main optical elements of the beamline are a …

High-accuracy radiometry in the EUV range at the PTB soft x-ray beamline

F Scholze, J Tümmler, G Ulm - Metrologia, 2003 - iopscience.iop.org
During the past decade, high-accuracy soft x-ray radiometry has increasingly gained in
importance. In particular, its routine availability is a prerequisite for the development of …

Characterization of an in-vacuum PILATUS 1M detector

J Wernecke, C Gollwitzer, P Müller… - Journal of Synchrotron …, 2014 - journals.iucr.org
A dedicated in-vacuum X-ray detector based on the hybrid pixel PILATUS 1M detector has
been installed at the four-crystal monochromator beamline of the PTB at the electron storage …

Thickness determination for Cu and Ni nanolayers: Comparison of completely reference-free fundamental parameter-based X-ray fluorescence analysis and X-ray …

M Kolbe, B Beckhoff, M Krumrey, G Ulm - Spectrochimica Acta Part B …, 2005 - Elsevier
Monochromatized synchrotron radiation of the electron storage ring BESSY II has been used
for the non-destructive thickness determination of nanolayered materials by two different …

High-accuracy EUV metrology of PTB using synchrotron radiation

F Scholze, B Beckhoff, G Brandt… - … and process control …, 2001 - spiedigitallibrary.org
The development of EUV lithography, has made high-accuracy at-wavelength metrology
necessary. Radiometry using synchrotron radiation has been performed by the German …

Surface layer determination for the Si spheres of the Avogadro project

I Busch, Y Azuma, H Bettin, L Cibik, P Fuchs, K Fujii… - Metrologia, 2011 - iopscience.iop.org
For the accurate determination of the Avogadro constant, two 28 Si spheres were produced,
whose macroscopic density, in addition to other values, must be determined. To make a …

Synchrotron-radiation-operated cryogenic electrical-substitution radiometer as the high-accuracy primary detector standard in the ultraviolet, vacuum-ultraviolet, and …

H Rabus, V Persch, G Ulm - Applied optics, 1997 - opg.optica.org
The accuracy of detector calibration in the UV, vacuum-ultraviolet, and soft-x-ray spectral
ranges could be significantly improved by the use of the synchrotron radiation electrical …