Comprehensive assessment of lightning protection schemes for 10 kV overhead distribution lines
J Cao, Y Du, Y Ding, R Qi, B Li… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
This paper presents an assessment of lightning protection schemes for overhead lines from
two aspects: protection performance and economic cost. Considering the random nature of …
two aspects: protection performance and economic cost. Considering the random nature of …
3D FEM analysis of induced current in the shield of the buried cable by non-vertical channel
AF Nematollahi, B Vahidi - Electric Power Systems Research, 2022 - Elsevier
The induced current in the buried cable shield is evaluated by solving the full-wave Maxwell
equations with the Finite Element Method (FEM). Three different cases are considered for …
equations with the Finite Element Method (FEM). Three different cases are considered for …
A self-decoupling contactless overvoltage measurement method based on optimization of measuring point
X Yan, J Wang, Z Shen, P Zhao, X Li… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
Contactless overvoltage measurement sensor has good foreground in the application of the
power system, and however, the difference in the installation position of the sensor will …
power system, and however, the difference in the installation position of the sensor will …
Measurement of lightning-induced overvoltage in power distribution lines using ceramic-capacitor insulator
Q Yang, L Yin, H Liu, K Wang… - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
The measurement of overvoltage in a power distribution network is the basis for detecting
lightning-induced overvoltage. This paper proposes a lightning-induced overvoltage …
lightning-induced overvoltage. This paper proposes a lightning-induced overvoltage …
Performance against direct lightning on 10-kV overhead distribution lines with counterpoise wires
J Cao, Y Du, Y Ding, Z Li, M Chen… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
This article investigates the lightning performance of a 10-kV overhead distribution line
equipped with grounding counterpoise wires under extremely low soil conductivity …
equipped with grounding counterpoise wires under extremely low soil conductivity …
3-D FDTD analysis of lightning-induced voltages in distribution lines due to inclined lightning
M Natsui, A Ametani, J Mahseredjian… - IEEE Transactions …, 2020 - ieeexplore.ieee.org
In this article, lightning-induced overvoltages due to inclined lightning are investigated by a
finite-difference timedomain (FDTD) method for distribution lines of a single conductor and a …
finite-difference timedomain (FDTD) method for distribution lines of a single conductor and a …
Analysis the effect of an ocean-land mixed propagation path on the induced voltage in overhead lines due to inclined lightning
AF Nematollahi, B Vahidi - Electric Power Systems Research, 2022 - Elsevier
In this paper, the induced overvoltage of the non-vertical lightning channel on the overhead
line in the presence of ocean-land mixed propagation is investigated. The lightning-induced …
line in the presence of ocean-land mixed propagation is investigated. The lightning-induced …
Lightning performance of aerial distribution lines with neutral wire and conductive poles
JOS Paulino, WC Boaventura… - 2018 34th International …, 2018 - ieeexplore.ieee.org
This paper presents a set of formulas to compute the peak-value of LIVs on aerial
distribution lines, considering the presence of a multi-grounded neutral in the line. The …
distribution lines, considering the presence of a multi-grounded neutral in the line. The …
Evaluation of lightning-related faults that lead to distribution network outages: An experimental case study
MA Ravaglio, KK Küster, SLF Santos… - Electric Power Systems …, 2019 - Elsevier
Lightning activity is often one of the major causes of voltage transient disturbances and
interruptions in distribution networks. Although important researches have been performed …
interruptions in distribution networks. Although important researches have been performed …
Analysis of lightning-induced voltages on a matched experimental overhead line
MNN Santos, A Piantini - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
This article presents an analysis of 64 lightning-induced voltage waveshapes recorded on a
2.7 km long, nonenergized experimental line located on the campus of the University of São …
2.7 km long, nonenergized experimental line located on the campus of the University of São …