3D‐printed patient‐specific instrumentation technique vs. conventional technique in medial open wedge high tibial osteotomy: a prospective comparative study

Y Mao, Y Xiong, Q Li, G Chen, W Fu… - BioMed Research …, 2020 - Wiley Online Library
Purpose. The purpose of this study was to compare the accuracy and clinical outcomes of
the medial open wedge high tibial osteotomy (MOWHTO) using a three‐dimensional (3D‐) …

Feasibility and 3D planning of a novel patient-specific instrumentation technique in medial opening-wedge high tibial osteotomy

W Van Genechten, W Van Tilborg… - The Journal of Knee …, 2021 - thieme-connect.com
A novel approach for opening-wedge high tibial osteotomy (OWHTO) with patient-specific
instrumentation (PSI) was evaluated for its safety, feasibility, and accuracy. Next, the …

Inter-observer and intra-observer reliability of mechanical axis alignment before and after total knee arthroplasty using long leg radiographs

A Bowman, M Shunmugam, AR Watts, DC Bramwell… - The Knee, 2016 - Elsevier
Abstract Background Long leg radiographs (LLRs) are commonly performed for assessment
of mechanical alignment and operative planning in patients undergoing total knee …

[HTML][HTML] Is the lateral tibial spine a reliable landmark for planning tibial or femoral valgus osteotomies?

M Tripon, P Sautet, JN Argenson, C Jacquet… - … & Traumatology: Surgery …, 2022 - Elsevier
Introduction A valgus osteotomy around the knee is a conservative procedure performed to
unload the medial tibiofemoral compartment. However, the optimal postoperative alignment …

Applicability of a modified angular correction measurement method for open-wedge high tibial osteotomy

J Moore, L Mychaltchouk, F Lavoie - Knee Surgery, Sports Traumatology …, 2017 - Springer
Purpose The purpose of this study was to evaluate the clinical potential of a new
measurement technique for open-wedge high tibial osteotomy (HTO) based on the medial …

Rotation or flexion alters mechanical leg axis measurements comparably in patients with different coronal alignment

L Jud, T Trache, T Tondelli, P Fürnstahl… - Knee Surgery …, 2020 - Wiley Online Library
Purpose Flexion and rotation of the knee joint are supposed to alter the measurement of the
mechanical leg axis on long leg radiographs. However, in patients with varus or valgus …

[HTML][HTML] Large deformity correction in medial open-wedge high tibial osteotomy may cause degeneration of patellofemoral cartilage: a retrospective study

E Otakara, S Nakagawa, Y Arai, H Inoue, H Kan… - Medicine, 2019 - journals.lww.com
To evaluate retrospectively any association between the degree of deformity correction by
medial open-wedge high tibial osteotomy (HTO) and patellofemoral joint degeneration. We …

Lateral tibial intercondylar eminence is a reliable reference for alignment correction in high tibial osteotomy

X Jiang, B Li, K Xie, S Ai, X Hu, L Gao… - Knee Surgery …, 2023 - Wiley Online Library
Purpose The purpose of the study is to determine whether the lateral tibial intercondylar
eminence (LTIE) is a reliable reference for alignment correction in high tibial osteotomy …

HKA angle—a reliable planning parameter for high tibial osteotomy: a theoretical analysis using standing whole-leg radiographs

X Jiang, K Xie, X Han, S Ai, H Wu… - The Journal of Knee …, 2022 - thieme-connect.com
High tibial osteotomy (HTO) is a recognized treatment for early-stage medial compartment
knee osteoarthritis. Preoperative planning with standing whole-leg radiographs (WLRs) is …

Intraoperative fluoroscopic assessment of limb alignment is a reliable predictor for postoperative limb alignment in biplanar medial opening-wedge high tibial …

KM Jang, JH Lee, IY Cho, BK Park, SB Han - The Journal of arthroplasty, 2017 - Elsevier
Background The purpose of this study was to assess the reliability of pre-, intra operative,
and postoperative limb alignment measurements and investigate the correlation between …