An approach for controlled reclosing of shunt-compensated transmission lines

KMC Dantas, WLA Neves… - IEEE transactions on …, 2013 - ieeexplore.ieee.org
An approach for controlled reclosing of transmission lines with shunt reactive compensation
is proposed here to reduce switching surge overvoltages. It consists of applying …

Transients caused by switching of 420 kV three-phase variable shunt reactor

A Župan, B Filipović-Grčić, D Filipović-Grčić - Electric power systems …, 2016 - Elsevier
This paper describes transients caused by uncontrolled and controlled switching of three-
phase 420 kV variable shunt reactor (VSR). The model for the analysis of the transients …

Challenges in field implementation of controlled energization for various equipment loads with circuit breakers considering diversified dielectric and mechanical …

U Parikh, BR Bhalja - International Journal of Electrical Power & Energy …, 2017 - Elsevier
The close coordination between circuit breaker (CB) characteristics and behavior of
equipment to be switched plays key role in achieving desired mitigation results during …

[PDF][PDF] Transients caused by uncontrolled and controlled switching of circuit breakers

I Uglešić, B Filipović-Grčić, S Bojić - The International Symposium on …, 2013 - academia.edu
This paper describes transients caused by uncontrolled and controlled switching of high-
voltage circuit breakers. Inrush currents due to shunt reactor energization were analyzed …

[PDF][PDF] Mitigation of temporary overvoltages in weak grids connected to DFIG-based wind farms

EA Awad, EA Badran, FMH Youssef - Journal of Electrical …, 2014 - researchgate.net
The level of temporary overvoltage (TOV) has a strong effect on wind turbine power system
reliability. TOV magnitude depends up on the state at which the circuit breaker contacts …

[PDF][PDF] Mitigation of switching overvoltages due to energization procedures in grid-connected offshore wind farms

EA Awad, EA Badran, FMH Youssef - International Journal of …, 2014 - academia.edu
This paper presents the mitigation of switching overvoltages which are generated due to
energization procedures in grid-connected to off-shore wind farms. Pre-insertion resistor …

[PDF][PDF] Real time implementation of transmission line controlled switching

KMC Dantas, WLA Neves, D Fernandes Jr… - … Conference on Power …, 2011 - ipstconf.org
A method for controlled switching of line circuit breakers is implemented in a prototype
device for real time evaluation. The switching strategy consists on finding a suitable circuit …

[PDF][PDF] Recursive digital filters design to compensate CVT frequency response: An application for transmission line controlled switching

KMC Dantas, EP Machado, WLA Neves… - Proc. Int. Conf. Power …, 2015 - ipstconf.org
In this work Recursive Digital Filters (RDF) are used to correct the inaccuracies of the
Capacitive Voltage Transformers (CVT) transient response to properly estimate the DC line …

Chaveamento controlado aplicado ao religamento rápido de linhas de transmissão.

KMC Dantas - 2012 - dspace.sti.ufcg.edu.br
Um novo método para religamento controlado de linhas de transmissão com compensação
reativa em derivação é proposto nesta tese. Este método baseia-se em técnicas simples …

[PDF][PDF] Analysis and mitigation techniques of switching overvoltages for A 500 kV transmission line

AS Shafy, AM Emam, SM Ghania… - Int. Electr. Eng. J …, 2016 - feng.stafpu.bu.edu.eg
When an overhead Transmission line is energized, transients overvoltages are generated in
the electrical networks including the line and the supply network that can be dangerous and …