Nondestructive characterization of bone tissue scaffolds for clinical scenarios
Objectives This study aimed to develop a simple and efficient numerical modeling approach
for characterizing strain and total strain energy in bone scaffolds implanted in patient …
for characterizing strain and total strain energy in bone scaffolds implanted in patient …
Pre-clinical characterization of a novel flexible surface stem design for total knee replacements
JO Sass, J Hembus, E Fuhrmann… - Proceedings of the …, 2023 - journals.sagepub.com
Primary stability is crucial for implant osseointegration and the long-term stability of
cementless total joint replacements. Biomechanical studies have shown the potential of …
cementless total joint replacements. Biomechanical studies have shown the potential of …
Influence of extension stem length and diameter on clinical and radiographic outcomes of revision total knee arthroplasty
Background Extension stems provide stability to revision total knee arthroplasty (RTKA).
Little is known regarding the relationship between stem characteristics and RTKA stability …
Little is known regarding the relationship between stem characteristics and RTKA stability …
[HTML][HTML] The effect of different interference fits on the primary fixation of a cementless femoral component during experimental testing
E Sánchez, C Schilling, TM Grupp, A Giurea… - journal of the …, 2021 - Elsevier
Cementless femoral total knee arthroplasty (TKA) components use a press-fit (referred to as
interference fit) to achieve initial fixation. A higher interference fit could lead to a superior …
interference fit) to achieve initial fixation. A higher interference fit could lead to a superior …
A randomized controlled trial comparing two-year postoperative femoral and tibial migration of a new and an established cementless rotating platform total knee …
LA Koster, R Rassir, BL Kaptein… - The Bone & Joint …, 2023 - boneandjoint.org.uk
Aims The primary aim of this study was to compare the migration of the femoral and tibial
components of the cementless rotating platform Attune and Low Contact Stress (LCS) total …
components of the cementless rotating platform Attune and Low Contact Stress (LCS) total …
[HTML][HTML] Experimental measurements of femoral primary stability in two cementless posterior-stabilized knee replacement implants
T Anijs, D Wolfson, A Mercer, M Rock… - Medical Engineering & …, 2022 - Elsevier
Sufficient primary stability through interference fit is required for bone ingrowth and
subsequent long-term fixation of cementless knee replacement implants, and can be …
subsequent long-term fixation of cementless knee replacement implants, and can be …
Optimal intersurface stability for unicompartmental femoral component design with two pegs placed on the distal resection surface: 5 mm peg length increment and 10 …
Y Sun, Z Li, K Zhao, D Dimitriou, B Yang… - Knee Surgery …, 2024 - Wiley Online Library
Purpose The present study aimed to identify the optimal design of the unicompartmental
femoral component through parameter analysis and stability evaluation. Methods A finite …
femoral component through parameter analysis and stability evaluation. Methods A finite …
Comparative biomechanical in vitro study of different modular total knee arthroplasty revision stems with bone defects
D Guttowski, V Polster, G Huber, MM Morlock… - The journal of …, 2020 - Elsevier
Background The aim of this study is to investigate the effects of different stem lengths and
types including cones on primary stability in revision total knee arthroplasty with different …
types including cones on primary stability in revision total knee arthroplasty with different …
[HTML][HTML] No effect in primary stability after increasing interference fit in cementless TKA tibial components
E Sánchez, C Schilling, TM Grupp, A Giurea… - journal of the …, 2021 - Elsevier
Cementless total knee arthroplasty (TKA) implants rely on interference fit to achieve initial
stability. However, the optimal interference fit is unknown. This study investigates the effect …
stability. However, the optimal interference fit is unknown. This study investigates the effect …
Debonding of coin-shaped osseointegrated implants: Coupling of experimental and numerical approaches
While cementless implants are now widely used clinically, implant debonding still occur and
is difficult to anticipate. Assessing the biomechanical strength of the bone–implant interface …
is difficult to anticipate. Assessing the biomechanical strength of the bone–implant interface …