Polymer gel dosimetry
Polymer gel dosimeters are fabricated from radiation sensitive chemicals which, upon
irradiation, polymerize as a function of the absorbed radiation dose. These gel dosimeters …
irradiation, polymerize as a function of the absorbed radiation dose. These gel dosimeters …
Radiation dosimetry by use of radiosensitive hydrogels and polymers: mechanisms, state-of-the-art and perspective from 3D to 4D
Y De Deene - Gels, 2022 - mdpi.com
Gel dosimetry was developed in the 1990s in response to a growing need for methods to
validate the radiation dose distribution delivered to cancer patients receiving high-precision …
validate the radiation dose distribution delivered to cancer patients receiving high-precision …
Chemical overview of gel dosimetry systems: a comprehensive review
MA Macchione, S Lechón Páez, MC Strumia… - Gels, 2022 - mdpi.com
Advances in radiotherapy technology during the last 25 years have significantly improved
both dose conformation to tumors and the preservation of healthy tissues, achieving almost …
both dose conformation to tumors and the preservation of healthy tissues, achieving almost …
Investigation of the PAGAT polymer gel dosimeter using magnetic resonance imaging
AJ Venning, B Hill, S Brindha, BJ Healy… - Physics in Medicine & …, 2005 - iopscience.iop.org
Investigation of the normoxic PAGAT polymer gel dosimeter has been undertaken. The
concentrations of the chemical components of the gel were varied and its response to …
concentrations of the chemical components of the gel were varied and its response to …
Clinical implementation of intensity-modulated arc therapy (IMAT) for rectal cancer
W Duthoy, W De Gersem, K Vergote… - International Journal of …, 2004 - Elsevier
PURPOSE: In rectal cancer, combined radiotherapy and chemotherapy, either pre-or
postoperatively, is an accepted treatment. Late small bowel (SB) toxicity is a feared side …
postoperatively, is an accepted treatment. Late small bowel (SB) toxicity is a feared side …
Polymer gel dosimeters with enhanced sensitivity for use in x-ray CT polymer gel dosimetry
A primary limitation of current x-ray CT polymer gel dosimetry is the low contrast, and hence
poor dose resolution, of dose images produced by the system. The low contrast is largely …
poor dose resolution, of dose images produced by the system. The low contrast is largely …
Investigation of tetrakis hydroxymethyl phosphonium chloride as an antioxidant for use in x-ray computed tomography polyacrylamide gel dosimetry
Of the antioxidants used to scavenge oxygen in polymer gel dosimeters, tetrakis
(hydroxymethyl) phosphonium chloride (THPC) has been shown to hold great promise due …
(hydroxymethyl) phosphonium chloride (THPC) has been shown to hold great promise due …
Technical considerations for implementation of x-ray CT polymer gel dosimetry
Gel dosimetry is the most promising 3D dosimetry technique in current radiation therapy
practice. X-ray CT has been shown to be a feasible method of reading out polymer gel …
practice. X-ray CT has been shown to be a feasible method of reading out polymer gel …
Cosolvent-free polymer gel dosimeters with improved dose sensitivity and resolution for x-ray CT dose response
JNM Chain, A Jirasek, LJ Schreiner… - Physics in Medicine & …, 2011 - iopscience.iop.org
This study reports new N-isopropylacrylamide (NIPAM) polymer gel recipes with increased
dose sensitivity and improved dose resolution for x-ray CT readout. NIPAM can be used to …
dose sensitivity and improved dose resolution for x-ray CT readout. NIPAM can be used to …
An x-ray CT polymer gel dosimetry prototype: II. Gel characterization and clinical application
H Johnston, M Hilts, J Carrick… - Physics in Medicine & …, 2012 - iopscience.iop.org
This article reports on the dosimetric properties of a new N-isopropylacrylamide, high% T,
polymer gel formulation (19.5% T, 23% C), optimized for x-ray computed tomography (CT) …
polymer gel formulation (19.5% T, 23% C), optimized for x-ray computed tomography (CT) …