Vacancy transfer probability parameters: Database and a new empirical value for elements in the atomic number range 16≤ Z≤ 92
In the present work, we offer a collection of documented values for vacancy transfer
probabilities (η XY, X= K, L i; Y= L, M, N, L i, M j, N p, O p; i= 1, 2, 3; j= 1, 2, 3, 4, 5; p= 1, 4, 5) …
probabilities (η XY, X= K, L i; Y= L, M, N, L i, M j, N p, O p; i= 1, 2, 3; j= 1, 2, 3, 4, 5; p= 1, 4, 5) …
Determination of the Kβ/Kα intensity ratios of silver in Ag-Cu alloys
AM Gójska, K Kozioł, EA Miśta-Jakubowska… - Nuclear Instruments and …, 2020 - Elsevier
The Ag-Kα and Ag-Kβ fluorescence lines induced by Rh X-ray tube have been observed.
The Ag Kβ/Kα intensity ratios for pure Ag and for Ag-Cu alloys have been obtained. The …
The Ag Kβ/Kα intensity ratios for pure Ag and for Ag-Cu alloys have been obtained. The …
K β to K α X-ray intensity ratios and K to L shell vacancy transfer probabilities of Co, Ni, Cu, and Zn
LFM Anand, SB Gudennavar, SG Bubbly… - Journal of Experimental …, 2015 - Springer
The K to L shell total vacancy transfer probabilities of low Z elements Co, Ni, Cu, and Zn are
estimated by measuring the K β to K α intensity ratio adopting the 2π-geometry. The target …
estimated by measuring the K β to K α intensity ratio adopting the 2π-geometry. The target …
K shell fluorescence parameters of some elements at 59.54 keV: Experimental and theoretical results
MF Turhan, F Akman - Nuclear Instruments and Methods in Physics …, 2023 - Elsevier
K α, K β and total K X-ray fluorescence cross-sections, K shell fluorescence yields, K β/K α X-
ray intensity ratios, K shell level widths, K shell life times, K to L shell vacancy transfer …
ray intensity ratios, K shell level widths, K shell life times, K to L shell vacancy transfer …
K to L shell vacancy transfer probabilities and Auger electron emission ratios for elements in the atomic range 30 ≤ Z ≤ 58
F Akman - Canadian Journal of Physics, 2016 - cdnsciencepub.com
The K to L shell vacancy transfer probabilities for some elements in the atomic range 30≤
Z≤ 58 were determined using the semi-empirical values of K shell fluorescence yield and …
Z≤ 58 were determined using the semi-empirical values of K shell fluorescence yield and …
Experimental values of K to Li sub-shell, K to L, and K to M shell vacancy transfer probabilities for some rare earth elements
F Akman - Applied Radiation and Isotopes, 2016 - Elsevier
The K to L i (i= 2, 3), K to L, and K to M shell vacancy transfer probabilities for La, Ce, Pr, Nd,
Sm, Eu, Gd, Tb, Dy and Er were determined at 59.54 keV using a reflection geometry. The …
Sm, Eu, Gd, Tb, Dy and Er were determined at 59.54 keV using a reflection geometry. The …
Chemical effect on K shell X-ray fluorescence parameters for some Mn and Ni compounds
K α, K β and total K X-ray fluorescence cross-sections, K shell fluorescence yields, K β/K α X-
ray intensity ratios, K to L shell vacancy transfer probabilities and Auger electrons emission …
ray intensity ratios, K to L shell vacancy transfer probabilities and Auger electrons emission …
Alloying effect on K to L shell vacancy transfer probabilities in 3d transition metals
The alloying effects on K to L shell vacancy transfer probabilities (ηKL) in 3d transition
metals have been carried out by X-ray fluorescence studies of various alloy compositions. K …
metals have been carried out by X-ray fluorescence studies of various alloy compositions. K …
FLUKA simulations of the target thickness dependence of Cu-K/K intensity ratios
AM Gójska, K Kozioł, EA Miśta-Jakubowska… - arXiv preprint arXiv …, 2023 - arxiv.org
The numerical Monte-Carlo simulations of Cu-K $\alpha $ and Cu-K $\beta $ fluorescence
lines induced by monoenergetic Am-241 radiation in copper have been presented. The …
lines induced by monoenergetic Am-241 radiation in copper have been presented. The …
K shell X-ray intensity ratios, K-Li, KL, and KM vacancy transfer probabilities of Ba and Tl following internal conversion process
PV Sreevidya, SB Gudennavar… - Canadian Journal of …, 2014 - cdnsciencepub.com
K shell X-rays of barium and thallium following internal conversion decay in Cs137 and
Hg203, respectively, were detected using a Si (Li) X-ray detector coupled to PC-based 8k …
Hg203, respectively, were detected using a Si (Li) X-ray detector coupled to PC-based 8k …