Modeling and stability issues of voltage-source converter-dominated power systems: A review
L Xiong, X Liu, Y Liu, F Zhuo - CSEE Journal of Power and …, 2020 - ieeexplore.ieee.org
With the substantive increase in the proportion of voltage-source converter (VSC)-based
equipment, traditional power systems that primarily constituted of synchronous generators …
equipment, traditional power systems that primarily constituted of synchronous generators …
Modular multilevel converters: Recent achievements and challenges
MA Perez, S Ceballos, G Konstantinou… - IEEE Open Journal …, 2021 - ieeexplore.ieee.org
The modular multilevel converter (MMC) is currently one of the power converter topologies
which has attracted more research and development worldwide. Its features, such as high …
which has attracted more research and development worldwide. Its features, such as high …
Power system stability with a high penetration of inverter-based resources
Inverter-based resources (IBRs) possess dynamics that are significantly different from those
of synchronous-generator-based sources and as IBR penetrations grow the dynamics of …
of synchronous-generator-based sources and as IBR penetrations grow the dynamics of …
Impedance modeling and analysis of MMC-HVDC for offshore wind farm integration
K Ji, G Tang, H Pang, J Yang - IEEE Transactions on Power …, 2019 - ieeexplore.ieee.org
The offshore ac side impedance model of the modular multilevel converter (MMC) based
high voltage direct current (HVdc) system is essential for analyzing the interaction stability …
high voltage direct current (HVdc) system is essential for analyzing the interaction stability …
[PDF][PDF] 面向柔直换流站高频谐振问题的换流变压器建模与参数辨识
胡应宏, 李雨, 李阳, 陈继开, 张扬 - 电工技术学报, 2024 - dgjsxb.ces-transaction.com
摘要围绕张北柔直康保站空母线高频谐振问题, 重点研究换流变压器在高频段呈现的阻抗特性与
建模方法, 并应用于模块化多电平换流器(MMC) 空母线高频谐振问题的分析 …
建模方法, 并应用于模块化多电平换流器(MMC) 空母线高频谐振问题的分析 …
A complete impedance model of a PMSG-based wind energy conversion system and its effect on the stability analysis of MMC-HVDC connected offshore wind farms
Impedance modeling of a permanent magnet synchronous generator (PMSG)-based wind
energy conversion system (WECS) usually ignores the machine-side dynamics, instead, the …
energy conversion system (WECS) usually ignores the machine-side dynamics, instead, the …
A generic small-signal stability criterion of DC distribution power system: Bus node impedance criterion (BNIC)
The dc distribution power system has drawn widespread attention and rapidly developed in
recent years; however, its stability issue is one of the urgent challenges, requiring much …
recent years; however, its stability issue is one of the urgent challenges, requiring much …
A complete HSS-based impedance model of MMC considering grid impedance coupling
Z Xu, B Li, L Han, J Hu, S Wang… - IEEE Transactions on …, 2020 - ieeexplore.ieee.org
Harmonic state space (HSS) is seen as an effective impedance modeling method to
precisely characterize the internal harmonic features of the modular multilevel converter …
precisely characterize the internal harmonic features of the modular multilevel converter …
Harmonic stability analysis of MMC-based DC system using DC impedance model
K Ji, G Tang, J Yang, Y Li, D Liu - IEEE Journal of Emerging …, 2019 - ieeexplore.ieee.org
The dc impedance model of a modular multilevel converter (MMC) is the basis for analyzing
harmonic resonances of MMC-based dc systems. As an MMC typifies a multiple harmonic …
harmonic resonances of MMC-based dc systems. As an MMC typifies a multiple harmonic …
Analysis and suppression control of high frequency resonance for MMC-HVDC system
Y Li, T An, D Zhang, X Pei, K Ji… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
The high-frequency resonances (HFRs) around 700 Hz and 1.8 kHz have occurred in Yu′
E project. Mechanism studies indicate that HFRs are caused by the interactions between the …
E project. Mechanism studies indicate that HFRs are caused by the interactions between the …