The determination of trace metal pollutants in environmental matrices using ion chromatography
MJ Shaw, PR Haddad - Environment International, 2004 - Elsevier
A review is presented detailing the development of ion chromatography (IC) as a selective
analytical tool for the determination of toxic metals and their organic species in many …
analytical tool for the determination of toxic metals and their organic species in many …
Advances in technologies for the measurement of uranium in diverse matrices
DPS Rathore - Talanta, 2008 - Elsevier
An overview of the advances in technologies, which can be used in the field as well as in a
laboratory for the measurement of uranium in diverse matrices like, waters, minerals …
laboratory for the measurement of uranium in diverse matrices like, waters, minerals …
Nanometer titanium dioxide immobilized on silica gel as sorbent for preconcentration of metal ions prior to their determination by inductively coupled plasma atomic …
Y Liu, P Liang, L Guo - Talanta, 2005 - Elsevier
Nanometer titanium dioxide immobilized on silica gel (immobilized nanometer TiO2) was
prepared by sol–gel method and characterized by using X-ray diffraction (XRD) and …
prepared by sol–gel method and characterized by using X-ray diffraction (XRD) and …
Trends in preconcentration procedures for metal determination using atomic spectrometry techniques
M de Godoi Pereira, MAZ Arruda - Microchimica Acta, 2003 - Springer
Methods for metal preconcentration are often described in the literature. However, purposes
are often different, depending on whether the methods are applied in environmental, clinical …
are often different, depending on whether the methods are applied in environmental, clinical …
Removal of copper (II) from aqueous phase by Purolite C100-MB cation exchange resin in fixed bed columns: Modeling
O Hamdaoui - Journal of hazardous materials, 2009 - Elsevier
The dynamic removal of copper by Purolite C100-MB cation exchange resin was studied in
packed bed columns. The values of column parameters are predicted as a function of flow …
packed bed columns. The values of column parameters are predicted as a function of flow …
Determination of copper, nickel, cobalt, silver, lead, cadmium, and mercury ions in water by solid-phase extraction and the RP-HPLC with UV-Vis detection
Q Hu, G Yang, Y Zhao, J Yin - Analytical and bioanalytical chemistry, 2003 - Springer
A new method for the simultaneous determination of seven heavy metal ions in water by
solid-phase extraction and reversed-phase high-performance liquid chromatography (RP …
solid-phase extraction and reversed-phase high-performance liquid chromatography (RP …
Preconcentration of lead with Amberlite XAD-2 and Amberlite XAD-7 based chelating resins for its determination by flame atomic absorption spectrometry
PK Tewari, AK Singh - Talanta, 2002 - Elsevier
Four chelating matrices prepared by coupling Amberlite XAD-2 with chromotropic acid
(AXAD-2-CA or 1), pyrocatechol (AXAD-2-PC or 2) and thiosalicylic acid (AXAD-2-TSA or 3) …
(AXAD-2-CA or 1), pyrocatechol (AXAD-2-PC or 2) and thiosalicylic acid (AXAD-2-TSA or 3) …
Metal ion enrichment with Amberlite XAD-2 functionalized with Tiron: analytical applications
Amberlite XAD-2 was functionalized with Tiron (disodium salt of 1, 2-dihydroxybenzene-3, 5-
disulfonic acid) by coupling it through an–NN–spacer. The resulting chelating resin …
disulfonic acid) by coupling it through an–NN–spacer. The resulting chelating resin …
Preparation of a chelating resin by immobilizing 1-(2-pyridylazo) 2-naphtol on amberlite XAD-16 and its application of solid phase extraction of Ni (II), Cd (II), Co (II) …
A polystyrene divinylbenzene resin (Amberlite XAD-16) functionalized by 1-(2-pyridylazo) 2-
naphtol has been synthesized and its sorption properties have been investigated for …
naphtol has been synthesized and its sorption properties have been investigated for …
Amberlite XAD-7 impregnated with Xylenol Orange: a chelating collector for preconcentration of Cd (II), Co (II), Cu (II), Ni (II), Zn (II) and Fe (III) ions prior to their …
PK Tewari, AK Singh - Fresenius' journal of analytical chemistry, 2000 - Springer
A new chelating resin, Xylenol Orange coated Amberlite XAD-7, was prepared and used for
preconcentration of Cd (II), Co (II), Cu (II), Fe (III), Ni (II) and Zn (II) prior to their determination …
preconcentration of Cd (II), Co (II), Cu (II), Fe (III), Ni (II) and Zn (II) prior to their determination …