[HTML][HTML] Systematic literature review on the benefit of patient protection shielding during medical X-ray imaging: towards a discontinuation of the current practice
ET Samara, N Saltybaeva, MS Merce, S Gianolini, M Ith - Physica Medica, 2022 - Elsevier
Purpose Patient shielding during medical X-ray imaging has been increasingly criticized in
the last years due to growing evidence that it often provides minimal benefit and may even …
the last years due to growing evidence that it often provides minimal benefit and may even …
Multiphase vascular lower limb computed tomography: assessment of patients doses and radiogenic risk
The purposes of this study are to estimate patient's radiation doses and radiogenic risk in
vascular lower limb computed tomography (CT). In total, 188 (109 (68%) males and 79 …
vascular lower limb computed tomography (CT). In total, 188 (109 (68%) males and 79 …
Reduction of scattered radiation dose by X-ray shielding during mammography
BY Koo, KS Lee - Radiation Physics and Chemistry, 2020 - Elsevier
Scattered X-rays during mammography can cause undesired increased exposure to
radiation during the generation of medical images, which could cause cancer because the …
radiation during the generation of medical images, which could cause cancer because the …
An investigation on protection properties of Tantalum (V) oxide reinforced glass screens on unexposed breast tissue for mammography examinations
HY Alan, G ALMisned, A Yilmaz, LA Susam, E Ilik… - Radiography, 2024 - Elsevier
Introduction The utilization of radiation shielding material positioned between the both
breasts are crucial for the reduction of glandular dose and the safeguarding of the …
breasts are crucial for the reduction of glandular dose and the safeguarding of the …
The effect of out-of-plane patient shielding on ct radiation exposure and tube current modulations: a phantom study across three vendors
J Rautiainen, MAK Juntunen… - Radiation Protection …, 2022 - academic.oup.com
The aim of this study was to evaluate how out-of-plane patient shielding affects radiation
exposure parameters and tube current modulation on different vendors' computed …
exposure parameters and tube current modulation on different vendors' computed …
[HTML][HTML] CT 受检者体表屏蔽防护存在的问题与对策
李润根, 时超刚, 白浩, 刘莹 - 中国辐射卫生, 2020 - html.rhhz.net
CT 非检查区域体表屏蔽防护是降低受检者辐射剂量简单而有效的方法, 也是国家行业标准规定
的基本要求. 一些调查报道回顾显示, 在我国的不同的地区和不同级别的医疗机构CT …
的基本要求. 一些调查报道回顾显示, 在我国的不同的地区和不同级别的医疗机构CT …
Assessment of dose reduction and image quality by barium composite shielding in head and chest CT
JW Lee, DC Kweon - Radiation Effects and Defects in Solids, 2020 - Taylor & Francis
The purpose of this study was to evaluate the dose and image to assess a shielding made of
barium sulfate for the protection of supersensitive radiation eye lens and superficial breast …
barium sulfate for the protection of supersensitive radiation eye lens and superficial breast …
Efficacy of breast shielding during head computed tomography examination
N Zalokar, N Mekis - Radiology and oncology, 2020 - sciendo.com
Background. Female breasts are exposed to scattered radiation regardless of not being
included in the primary field during head CT. This study aimed to investigate whether the …
included in the primary field during head CT. This study aimed to investigate whether the …
Absorbed dose and image quality according to the scan mode and shield position in pediatric brain computed tomography scans
E Bae, Y Cho, S Kim - Radiation Protection Dosimetry, 2023 - academic.oup.com
In this study, computed tomography dose index (CTDIvol), dose-length product (DLP), organ
dose and signal-to-noise ratio (SNR) were measured in pediatric brain helical and …
dose and signal-to-noise ratio (SNR) were measured in pediatric brain helical and …
[HTML][HTML] CT 扫描野内表面防护不同材料的防护效果以及对图像质量的影响
王倩, 冯世超, 梁媛, 马霄虹, 赵心明, 刘霞, 綦维维 - 中国辐射卫生, 2018 - html.rhhz.net
目的评价两种表面防护材料在CT 扫描野内的辐射防护效果和扫描野的图像质量. 方法使用CTDI
模体测量颈部扫描时周边的辐射量及CTDI w, 采用铋屏蔽和硫酸钙屏蔽为辐射防护材料的辐射 …
模体测量颈部扫描时周边的辐射量及CTDI w, 采用铋屏蔽和硫酸钙屏蔽为辐射防护材料的辐射 …