AE monitoring of real structures: applications, strengths, and limitations
T Schumacher, B Schechinger, T Vogel - Acoustic Emission Testing …, 2022 - Springer
The acoustic emission (AE) technique has been successfully used for decades to monitor
fracture processes during laboratory testing. This final chapter discusses deliberations …
fracture processes during laboratory testing. This final chapter discusses deliberations …
Post-earthquake Damage Assessment of Reinforced Concrete Members Using Combined Passive and Active Ultrasonic Stress Wave Monitoring
In earthquake-prone regions such as the United States' Pacific Northwest, post-event
damage assessment tools are needed to enable safe and speedy recovery missions …
damage assessment tools are needed to enable safe and speedy recovery missions …
Ultrasonic coda wave monitoring of concrete structures: First experiences with large-scale experiments and real structures
E Niederleithinger, X Wang, N Epple… - Bridge Maintenance …, 2021 - taylorfrancis.com
Ultrasonic monitoring, making use of the sensitivity of the coda of repeated transmission
measurements to changes in stress, temperature, moisture, as well as localized or …