A patient-specific closed-loop epilepsy management SoC with one-shot learning and online tuning

M Zhang, L Zhang, CW Tsai… - IEEE Journal of Solid-State …, 2022 - ieeexplore.ieee.org
Epilepsy treatment in clinical practices with surface electroencephalogram (EEG) often faces
training dataset shortage issue, which is aggravated by seizure pattern variation among …

A 1.8–GΩ Input-Impedance 0.15–μV Input-Referred–Ripple Chopper Amplifier With Local Positive Feedback and SAR-Assisted Ripple Reduction

T Qu, Q Pan, L Liu, X Zeng, Z Hong… - IEEE Journal of Solid …, 2022 - ieeexplore.ieee.org
This article presents a chopper-stabilized multipath current-feedback instrumentation
amplifier (CFIA) that can also be reconfigured to a general-purpose operational amplifier …

An active concentric electrode for concurrent EEG recording and body-coupled communication (BCC) data transmission

T Tang, L Yan, JH Park, H Wu, L Zhang… - … Circuits and Systems, 2020 - ieeexplore.ieee.org
This paper presents a wearable active concentric electrode for concurrent EEG monitoring
and Body-Coupled Communication (BCC) data transmission. A three-layer concentric …

Analog Front-end Input-Impedance Boosting Techniques for Bio-Potential Monitoring—A Review

F Yan, J Liu - IEEE Transactions on Instrumentation and …, 2024 - ieeexplore.ieee.org
Physiological information provided by bio-potential signals is essential and pivotal for
biomedical sensors. As the first stage in the signal chain of the sensor, impedance matching …

An 8.7 μJ/class. FFT accelerator and DNN-based configurable SoC for Multi-Class Chronic Neurological Disorder Detection

Z Taufique, B Zhu, G Coppola… - 2021 IEEE Asian …, 2021 - ieeexplore.ieee.org
Chronic Neurological Disorders (CNDs) such as epilepsy [1],[2], migraine [3], and autism [4]
can be persistent for extensive periods. Untreated CNDs may lead to perpetual debilities …

A Single-Stage, Capacitively-Coupled Instrumentation Amplifier With Complementary Transimpedance Boosting

KA Ng, L Zhang, H Wu, T Tang… - IEEE Transactions on …, 2024 - ieeexplore.ieee.org
Capacitively-Coupled Instrumentation Amplifiers (CCIAs) are widely used as AC-coupled,
low-noise amplifiers in many multi-channel, area-intensive sensor interface applications …

A 13.2-kSPS Data Rate, 5.1-G Input Impedance Read-Out IC for DC Measurements

J Park, W Kim, D Han, H Lee, S Kim… - IEEE Transactions on …, 2025 - ieeexplore.ieee.org
A high input impedance read-out integrated circuit (IC) for DC measurements has been
implemented. The proposed read-out IC consists of a capacitively coupled instrumentation …

A 4.43 TΩ ZIN 0.0128 mm2 Cascaded Instrumentation Amplifier with Input-biased Pseudo Resistor for Implantable Brain Machine Interfaces

T Tang, Z Xu, Y Wei, L Feng, K Xu… - 2023 45th Annual …, 2023 - ieeexplore.ieee.org
A cascaded instrumentation amplifier (CaIA) with input-biased pseudo resistors (IBPR) is
presented for implantable brain machine interfaces (BMI). The gain distribution of two-stage …

Review of AI-on-the-edge EEG-based patient-specific epilepsy tracking SoCs

L Zhang, M Zhang, CW Tsai… - 2022 20th IEEE …, 2022 - ieeexplore.ieee.org
This paper reviews state-of-the-art AI-on-the-edge EEG-based patient-specific epilepsy
tracking System-on-Chips (SoCs). For ambulatory tracking and effective treatment of …

Inverter-Based Pseudo-Differential Reconfigurable Pixel Circuit Array for Multimodal and High-Density Neural Recordings

T Lee, M Je - 2022 IEEE International Symposium on Circuits …, 2022 - ieeexplore.ieee.org
This paper presents the inverter-based pseudo-differential reconfigurable pixel array. For
monitoring multi-modal neural activity, the pixel array can change its recording configuration …