A cycle configuration for large-scale helium refrigerator for fusion devices towards complete mitigation of the effects of pulsed heat load
Large-scale helium refrigerators in fusion devices work in pulsed heat load condition. The
immediate effect of pulsed heat load is mass flow rate fluctuation at the low pressure return …
immediate effect of pulsed heat load is mass flow rate fluctuation at the low pressure return …
[PDF][PDF] Designing process plant with pulsating loads: Exergy analysis of helium plants for fusion reactors
Cryogenic plants operate, typically, in the temperature range of 4.2 K to 123 K with
applications in medical and biological fields, in aerospace engineering, in superconductivity …
applications in medical and biological fields, in aerospace engineering, in superconductivity …