[HTML][HTML] Adaptive optics imaging of the human retina

SA Burns, AE Elsner, KA Sapoznik, RL Warner… - Progress in retinal and …, 2019 - Elsevier
Adaptive Optics (AO) retinal imaging has provided revolutionary tools to scientists and
clinicians for studying retinal structure and function in the living eye. From animal models to …

[HTML][HTML] Linear birefringence of the central human cornea

RW Knighton, XR Huang - Investigative ophthalmology & visual …, 2002 - arvojournals.org
purpose. To determine the polarization properties of the central cornea at perpendicular
incidence in a normal human population on the assumption that the cornea behaves as a …

Mueller matrix retinal imager with optimized polarization conditions

KM Twietmeyer, RA Chipman, AE Elsner, Y Zhao… - Optics express, 2008 - opg.optica.org
A new Mueller matrix polarimeter was used to image the retinas of normal subjects. Light
from a linearly polarized 780 nm laser was passed through a system of variable retarders …

Polarimetric imaging of biological tissues based on the indices of polarimetric purity

A Van Eeckhout, A Lizana… - Journal of …, 2018 - Wiley Online Library
We highlight the interest of using the indices of polarimetric purity (IPPs) to the inspection of
biological tissues. The IPPs were recently proposed in the literature and they result in a …

Spatially resolved polarization properties for in vitro corneas

JM Bueno, J Jaronski - Ophthalmic and Physiological Optics, 2001 - Wiley Online Library
Spatially resolved polarization properties of in vitro mammalian corneas have been studied
by using a Mueller‐matrix imaging polarimeter in transmission mode. Sixteen images …

Measurements of the corneal birefringence with a liquid-crystal imaging polariscope

JM Bueno, F Vargas-Martín - Applied optics, 2002 - opg.optica.org
An imaging polariscope has been used to analyze the spatially resolved polarization
properties of living human corneas. The apparatus is a modified double-pass setup …

New optical scheme for a polarimetric-based glucose sensor

RR Ansari, S Bo¨ ckle, L Rovati - Journal of biomedical optics, 2004 - spiedigitallibrary.org
A new optical scheme to detect glucose concentration in the aqueous humor of the eye is
presented. The ultimate aim is to apply this technique in designing a new instrument for …

Mapping of corneal birefringence in thin and asymmetric keratoconus corneas with ultrahigh-resolution polarization-sensitive OCT

R Patil, R Shetty, R Narasimhan, Y Patel… - Journal of Cataract & …, 2022 - journals.lww.com
Purpose: To evaluate phase retardation (PR) across healthy eyes and eyes with thin
corneas (< 500 μm) and with asymmetric and bilateral keratoconus (KC). Setting: Narayana …

[HTML][HTML] Improved contrast of subretinal structures using polarization analysis

SA Burns, AE Elsner… - … & visual science, 2003 - tvst.arvojournals.org
purpose. To improve the ability to detect and quantify the early retinal changes associated
with aging, age-related maculopathy, and age-related macular degeneration. methods. A …

Quantifying external and internal collagen organization from Stokes-vector-based second harmonic generation imaging polarimetry

FJ Ávila, O Del Barco, JM Bueno - Journal of Optics, 2017 - iopscience.iop.org
Collagen organization has been analyzed at both external and internal scales by combining
Stokes-vector polarimetry and second harmonic generation microscopy. A significant linear …