Response study of a 51-story-tall Los Angeles, California building inferred from motions of the Mw7. 1 July 5, 2019 Ridgecrest, California earthquake

M Çelebi, D Swensen, H Haddadi - Bulletin of Earthquake Engineering, 2021 - Springer
A 51-story building in downtown Los Angeles that is equipped with a seismic monitoring
accelerometric array recorded the Mw7. 1 Ridgecrest, California earthquake of July 5, 2019 …

Ambient response of a unique performance‐based design tall building with dynamic response modification features

M Çelebi, M Huang, A Shakal, J Hooper… - … Structural Design of …, 2013 - Wiley Online Library
SUMMARY A 64‐story, performance‐based design building with reinforced concrete core
shear walls and unique dynamic response modification features (tuned liquid sloshing …

Temperature measurement assisted modal tracking of an instrumented building

WM González, RL Boroschek, JA Bilbao - Engineering Structures, 2021 - Elsevier
Abstract In Structural Health Monitoring (SHM), the instrumentation policies for buildings
usually require large numbers of high-resolution sensors. The relatively high economic cost …

Vibration-based temporary monitoring of a 253 m tall skew-plan building in Istanbul

OC Celik, E Budak, H Sucuoğlu - Earthquake Spectra, 2023 - journals.sagepub.com
A 253 m tall office building in Istanbul with a parallelogram footprint, which has 62 stories in
total, 54 tower stories above and 8 podium stories below grade, was monitored using 92 …

S2HM of Buildings in USA

M Çelebi - Seismic Structural Health Monitoring: From Theory to …, 2019 - Springer
The evolution of seismic structural-health monitoring (S 2 HM) of buildings in the USA is
described in this chapter, emphasizing real-time monitoring. Rapid and accurate …

Deprem Öncesi, Sırası ve Sonrasında Bir Yüksek Binanın Yapı Sağlığının İzlenmesi

E Aytulun, S Soyöz - Türk Deprem Araştırma Dergisi, 2020 - dergipark.org.tr
İstanbul gibi depremselliğin yüksek olduğu bölgelerde yüksek binaların deprem sonrasında
durumunun belirlenmesi gereklidir. Günümüzde deprem sonrası hasar tespiti genellikle …

COLLAPSE FRAGILITY ANALYSIS OF REINFORCED CONCRETE TALL BUILDINGS

E Budak - 2022 - open.metu.edu.tr
Seismic performance of a 253 m tall reinforced concrete core wall building in Istanbul,
designed according to performance-based seismic design principles, was assessed to …

Building Structural Health Monitoring Under Earthquake and Blasting Loading: The Chilean Experience

R Boroschek, P Villalpando, E Peña - Seismic Structural Health Monitoring …, 2019 - Springer
Near real-time structural health monitoring (SHM) has been used in Chile since mid-2009.
Chile is located in one of the most active seismic zones in the world so initially SHM was …

[PDF][PDF] DYNAMIC RESPONSE AND DESIGN EFFECT OF VERTICAL SEISMIC COMPONENTS IN TALL BUILDINGS

R Boroschek, D Cares - wcee.nicee.org
For design, the vertical seismic component is generally ignored, or it is considered as an
additional static load. The dynamic characteristics of the overall structure in the vertical …

[引用][C] Real-time monitoring of a steel building and its performance analysis

A Sagir - 2014 - Fen Bilimleri Enstitüsü