[HTML][HTML] In vivo dosimetry in external beam photon radiotherapy: Requirements and future directions for research, development, and clinical practice

I Olaciregui-Ruiz, S Beddar, P Greer, N Jornet… - Physics and imaging in …, 2020 - Elsevier
External beam radiotherapy with photon beams is a highly accurate treatment modality, but
requires extensive quality assurance programs to confirm that radiation therapy will be or …

Review of real time 2D Dosimetry in External Radiotherapy: Advancements and Techniques

L de Freitas Nascimento, A Gasparini - Radiation Measurements, 2024 - Elsevier
The objective of this paper is to provide a comprehensive review of the advancements and
techniques in real time two-dimensional (2D) dosimetry for external radiation therapy with …

Electronic portal imaging device dosimetry

B McCurdy, P Greer, J Bedford - Clinical 3D dosimetry in modern …, 2017 - taylorfrancis.com
Historically, several different electronic technologies have been utilized to replace the role of
radiographic films in capturing the images, including the scanning liquid ionization chamber …

[HTML][HTML] Beam output checks of a commercial high-field magnetic resonance-guided radiotherapy machine with its on-board megavoltage imager

GC Hilgers, M Ikink, I Potters, D Schuring - Physics and Imaging in …, 2023 - Elsevier
Beam output checks of a commercial high-field magnetic resonance-guided radiotherapy
machine can be performed with its on-board megavoltage imager (MVI). This is a fast and …

[HTML][HTML] Remote dosimetric auditing for intensity modulated radiotherapy: a pilot study

N Miri, J Lehmann, K Legge, BJ Zwan, P Vial… - Physics and Imaging in …, 2017 - Elsevier
Abstract Background and Purpose Electronic portal imaging devices (EPIDs) can be used to
reconstruct dose inside a virtual phantom. This work aims to study the feasibility of using this …

Intensity‐modulated radiation therapy dose verification using fluence and portal imaging device

I Sumida, H Yamaguchi, IJ Das, H Kizaki… - Journal of Applied …, 2016 - Wiley Online Library
Patient‐specific quality assurance for intensity‐modulated radiation therapy (IMRT) dose
verification is essential. The aim of this study is to provide a new method based on the …

Deep learning‐based tools to distinguish plan‐specific from generic deviations in EPID‐based in vivo dosimetry

I Olaciregui‐Ruiz, R Simões, S Jan‐Jakob - Medical Physics, 2024 - Wiley Online Library
Background Dose distributions calculated with electronic portal imaging device (EPID)‐
based in vivo dosimetry (EIVD) differ from planned dose distributions due to generic and …

Assessing focal spot alignment in clinical linear accelerators: a comprehensive evaluation with triplet phantoms

HL Riis, KH Engstrøm, L Slama, J Dass… - … Engineering Sciences in …, 2024 - Springer
A fundamental parameter to evaluate the beam delivery precision and stability on a clinical
linear accelerator (linac) is the focal spot position (FSP) measured relative to the collimator …

[HTML][HTML] Characterization of the on-board megavoltage imager in a magnetic resonance-guided radiotherapy machine for beam output checks

GC Hilgers, M Ikink, I Potters, D Schuring… - Physics and Imaging in …, 2024 - Elsevier
We characterized the on-board megavoltage imager (MVI) of a magnetic resonance-guided
radiotherapy machine for beam output checks. Linearity and repeatability of its dose …

In silico investigation of factors affecting the MV imaging performance of a novel water-equivalent EPID

SJ Blake, Z Cheng, S Atakaramians, S Meikle, M Lu… - Physica Medica, 2016 - Elsevier
Purpose AG eant 4 model of a novel, water-equivalent electronic portal imaging device