Ultralow emittance electron beams from a laser-wakefield accelerator
R Weingartner, S Raith, A Popp, S Chou, J Wenz… - Physical Review Special …, 2012 - APS
Using quadrupole scan measurements we show laser-wakefield accelerated electrons to
have a normalized transverse emittance of 0.21-0.02+ 0.01 π mm mrad at 245 MeV. We …
have a normalized transverse emittance of 0.21-0.02+ 0.01 π mm mrad at 245 MeV. We …
Subpicosecond electro-optic measurement of relativistic electron pulses
X Yan, AM MacLeod, WA Gillespie, GMH Knippels… - Physical Review Letters, 2000 - APS
Time-resolved measurements of the transverse electric field associated with relativistic
electron bunches are presented. Using an ultrafast electro-optic sensor close to the electron …
electron bunches are presented. Using an ultrafast electro-optic sensor close to the electron …
Observation of deflection of a beam of multi-GeV electrons by a thin crystal
U Wienands, TW Markiewicz, J Nelson, RJ Noble… - Physical review …, 2015 - APS
We report on an experiment performing channeling and volume reflection of a high-energy
electron beam using a quasimosaic, bent silicon (111) crystal at the End Station A Test …
electron beam using a quasimosaic, bent silicon (111) crystal at the End Station A Test …
Vibrating wire monitor: Versatile instrumentation for particle and photon beam measurements with wide dynamic range
SG Arutunian, AV Margaryan… - Journal of …, 2021 - iopscience.iop.org
The vibrating wire monitor proposed herein is based on the strong dependence of the
frequency of the pinched wire on its temperature. This dependence allows the measurement …
frequency of the pinched wire on its temperature. This dependence allows the measurement …
Observation of self-amplified spontaneous emission and exponential growth at 530 nm
Experimental evidence for self-amplified spontaneous emission (SASE) at 530 nm is
reported. The measurements were made at the low-energy undulator test line facility at the …
reported. The measurements were made at the low-energy undulator test line facility at the …
Saturation of a Ce:Y3Al5O12 scintillator response to ultra-short pulses of extreme ultraviolet soft X-ray and X-ray laser radiation
J Krzywinski, A Andrejczuk, RM Bionta… - Optical Materials …, 2017 - opg.optica.org
Investigations of radioluminescence saturation in monocrystalline cerium doped yttrium
aluminum garnet (Ce: YAG) exposed to intense extreme ultraviolet (XUV), soft X-ray and X …
aluminum garnet (Ce: YAG) exposed to intense extreme ultraviolet (XUV), soft X-ray and X …
Tailoring and optimization of LuAG: Ce epitaxial film scintillation properties by Mg co-doping
P Prusa, M Kučera, V Babin, P Bruza… - Crystal Growth & …, 2018 - ACS Publications
Six Mg co-doped Lu3Al5O12: Ce scintillating films were prepared by a liquid phase epitaxy
method, having Mg concentration of 0–3000 ppm. The following luminescence and …
method, having Mg concentration of 0–3000 ppm. The following luminescence and …
Electron beam profile imaging in the presence of coherent optical radiation effects
C Behrens, C Gerth, G Kube, B Schmidt, S Wesch… - Physical Review Special …, 2012 - APS
High-brightness electron beams with low energy spread at existing and future x-ray free-
electron lasers are affected by various collective beam self-interactions and microbunching …
electron lasers are affected by various collective beam self-interactions and microbunching …
Dose rate effects in fluorescence chemical dosimeters exposed to picosecond electron pulses: An accurate measurement of low doses at high dose rates
M Precek, P Kubelik, L Vysin… - Radiation …, 2022 - meridian.allenpress.com
The development of ultra-intense electron pulse for applications needs to be accompanied
by the implementation of a practical dosimetry system. In this study four different systems …
by the implementation of a practical dosimetry system. In this study four different systems …
Image of the transverse bunch profile via coherent optical transition radiation
A Potylitsyn, L Sukhikh, T Gusvitskii, G Kube… - … review accelerators and …, 2020 - APS
The use of optical transition radiation (OTR) monitors is a standard technique to measure
transverse beam profiles at many electron accelerators. With modern accelerator technology …
transverse beam profiles at many electron accelerators. With modern accelerator technology …