Control algorithms of shunt active power filter for harmonics mitigation: A review

Y Hoon, MA Mohd Radzi, MK Hassan, NF Mailah - Energies, 2017 - mdpi.com
Current harmonics is one of the most significant power quality issues which has attracted
tremendous research interest. Shunt active power filter (SAPF) is the best solution to …

Shunt active power filter: A review on phase synchronization control techniques

Y Hoon, MA Mohd Radzi, MAA Mohd Zainuri… - Electronics, 2019 - mdpi.com
Owing to the destructive impacts of harmonic currents, the topic of reducing their impacts on
power system has attracted tremendous research interests. In this regard, a shunt active …

Operation of three-level inverter-based shunt active power filter under nonideal grid voltage conditions with dual fundamental component extraction

Y Hoon, MAM Radzi, MK Hassan… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
In this paper, a new reference current generation method is proposed for effective harmonics
mitigation and reactive power compensation of three-level neutral-point diode clamped …

[HTML][HTML] A novel negative feedback phase locked loop-based reference current generation technique for shunt active power filter

PK Barik, G Shankar, PK Sahoo, RM Elavarasan… - International Journal of …, 2023 - Elsevier
The use of nonlinear devices introduces current and voltage harmonics into power
distribution networks. The presence of harmonics, an undesirable power quality issue …

An adaptive variable leaky least mean square control scheme for grid integration of a PV system

A Bag, B Subudhi, PK Ray - IEEE Transactions on Sustainable …, 2019 - ieeexplore.ieee.org
This paper presents a new grid synchronization control scheme for integrating a 3-phase PV
system to a grid. The Leaky Least Mean Square (LLMS) algorithm uses the fixed value for …

Modified synchronous reference frame based shunt active power filter with fuzzy logic control pulse width modulation inverter

S Musa, MA Mohd Radzi, H Hizam, NI Abdul Wahab… - Energies, 2017 - mdpi.com
Harmonic distortion in power networks has greatly reduced power quality and this affects
system stability. In order to mitigate this power quality issue, the shunt active power filter …

Integration of wind power generation through an enhanced instantaneous power theory

B Sahoo, SK Routray, PK Rout - IET Energy Systems Integration, 2020 - Wiley Online Library
This study deals with the operation of the wind power generation system (WPGS) having
active filter capabilities using the grid‐interfacing converter (GIC) control approach. A novel …

[PDF][PDF] A simplified synchronous reference frame for indirect current controlled three-level inverter-based shunt active power filters

Y Hoon, MAM Radzi, MK Hassan… - Journal of Power …, 2016 - koreascience.kr
This paper presents a new simplified harmonics extraction algorithm based on the
synchronous reference frame (SRF) for an indirect current controlled (ICC) three-level …

Design and prototyping of single‐phase shunt active power filter for harmonics elimination using model predictive current control

R Kanagavel, I Vairavasundaram… - … on Electrical Energy …, 2020 - Wiley Online Library
A model predictive current control (MPCC)‐based single‐phase shunt active power filter
(SAPF) is proposed in this manuscript to improve power quality by harmonics and reactive …

A dual fundamental current extraction controller for DSTATCOM in the distribution system for power quality improvement under non-ideal source voltage condition

A Ram, PR Sharma, RK Ahuja… - … Power Components and …, 2023 - Taylor & Francis
Most of the controllers often fail to work properly when encountered with power quality (PQ)