Power system stability enhancement by WAMS-based supplementary control of multi-terminal HVDC networks
J Machowski, P Kacejko, Ł Nogal, M Wancerz - Control Engineering …, 2013 - Elsevier
This paper deals with supplementary control of a MTDC network designed for the stability
enhancement of a AC power system. The proposed control is a WAMS-based control …
enhancement of a AC power system. The proposed control is a WAMS-based control …
Overview and test results of modern pilot schemes for coordination of line distance protection relays
E Bartosiewicz, R Kowalik… - 2013 12th International …, 2013 - ieeexplore.ieee.org
The paper presents a short review of pilots schemes, which are available in modern line
distance protection relays, and example results of common pilot schemes tests with the …
distance protection relays, and example results of common pilot schemes tests with the …
The construction and operation of some examples of MERGING UNITS
D Rasolomampionona, R Kowalik… - 2014 IEEE …, 2014 - ieeexplore.ieee.org
The submitted paper describes the construction of modern digital equipment protection
automation using Ethernet technology as the main medium of information exchange …
automation using Ethernet technology as the main medium of information exchange …
The design and operation of IEC61850-based transformer measuring device
P Kopański, R Kowalik… - 2014 IEEE …, 2014 - ieeexplore.ieee.org
The submitted paper contains results obtained from the HV transformer monitoring with the
use of IEC61850-based communications data system. One of the main characteristics of the …
use of IEC61850-based communications data system. One of the main characteristics of the …
Enhancing stability of a weakly connected AC power system by supplementary control of embedded HVDC lines
Ł Nogal - 2013 12th International Conference on Environment …, 2013 - ieeexplore.ieee.org
This paper deals with supplementary control of HVDC lines embedded to a weakly
connected AC transmission system in order to enlarge power transfer ability and to enhance …
connected AC transmission system in order to enlarge power transfer ability and to enhance …
Results of modern pilot schemes tests for general electric line protection devices
E Bartosiewicz, M Januszewski… - 2013 IEEE Grenoble …, 2013 - ieeexplore.ieee.org
The paper presents some results of modern pilot schemes tests and the testing methods
description. Distance protection coordination functions have been tested for GE Multilin UR …
description. Distance protection coordination functions have been tested for GE Multilin UR …
[PDF][PDF] Test results of modern pilot schemes for coordination of line distance protection relays
E Bartosiewicz, R Kowalik, M Januszewski - Przegląd Elektrotechniczny, 2013 - pe.org.pl
The paper presents example results of modern pilot schemes tests and the testing methods
description. Distance protection coordination functions have been tested for GE Multilin UR …
description. Distance protection coordination functions have been tested for GE Multilin UR …
[PDF][PDF] The Construction and Operation of Some Examples of Merging Unit
K Gontarz, M Januszewski… - Acta …, 2014 - yadda.icm.edu.pl
The paper describes schemes of modern digital protection automation devices using
Ethernet technology as the main medium of exchange of information, which allows building …
Ethernet technology as the main medium of exchange of information, which allows building …
Overview and Example Test Results of Modern Pilot Schemes for Coordination of Line Distance Protection Relays
E Bartosiewicz, R Kowalik, M Januszewski - Acta Energetica, 2014 - actaenergetica.org
The paper presents a short review of pilot schemes which are available in modern line
distance protection relays, and example results of common pilot scheme tests with the …
distance protection relays, and example results of common pilot scheme tests with the …
[PDF][PDF] Modern pilot schemes for coordination of line distance protection relays
E Bartosiewicz, D Rasolomampionona… - Przegląd …, 2013 - pe.org.pl
The paper presents a short review of common pilot schemes which are available in modern
line distance protection relays. Some differences in implementations of selected pilot …
line distance protection relays. Some differences in implementations of selected pilot …