Analysis of dose distribution according to the initial electron beam of the linear accelerator: a Monte Carlo study
H Park, HJ Choi, JI Kim, CH Min - Journal of Radiation Protection …, 2018 - koreascience.kr
Background: Monte Carlo (MC) simulation is the most accurate for calculating radiation dose
distribution and determining patient dose. In MC simulations of the therapeutic accelerator …
distribution and determining patient dose. In MC simulations of the therapeutic accelerator …
Analysis of characteristics and validation of 6 MV photon beam produced by Elekta Synergy linear accelerator using EGSnrc Monte Carlo code
E Gündem, B Dirican - Radiation Physics and Chemistry, 2021 - Elsevier
The most important step of the Monte Carlo (MC) dose calculation is the correct modelling of
the radiation device. This study was aimed to determine the initial electron beam …
the radiation device. This study was aimed to determine the initial electron beam …
[PDF][PDF] Determination of primary electron beam parameters in a Siemens Primus Linac using Monte Carlo simulation
DS Makrani, H Hasanzadeh… - … of Advances in …, 2015 - journals.sbmu.ac.ir
ABSTRACT The Monte Carlo method can be used to describe any technique that
approximates solutions to quantitative problems through statistical sampling. This method is …
approximates solutions to quantitative problems through statistical sampling. This method is …
Varian Clinac 2100 linear accelerator simulation employing PRIMO phase space model
Introduction The lack of information concerning the geometry and the chemical elements that
constitute the components of the linear accelerator is a real problem that is encountered by …
constitute the components of the linear accelerator is a real problem that is encountered by …
[HTML][HTML] Monte Carlo modeling of multileaf collimators using the code Geant4
ACH de Oliveira, JW Vieira, FRA Lima - Brazilian Journal of Radiation …, 2015 - bjrs.org.br
Radiotherapy uses various techniques and equipment for local treatment of cancer. The
equipment most often used in radiotherapy to the patient irradiation is linear accelerator …
equipment most often used in radiotherapy to the patient irradiation is linear accelerator …
Distributions dose analysis for 6 MV photon beams using Monte Carlo-GEANT4 simulation
Monte Carlo is a method that widely used for calculation of particle transport in radiotherapy
dose distribution. This study was devoted to develop a linear accelerator head geometry …
dose distribution. This study was devoted to develop a linear accelerator head geometry …
A new wedge-shaped ionization chamber component module for BEAMnrc to model the integral quality monitoring system®
OM Oderinde, FCP Du Plessis - Radiation Physics and Chemistry, 2017 - Elsevier
The purpose of this study was to develop a new component module (CM) namely IQM to
accurately model the integral quality monitoring (IQM) system® to be used in the BEAMnrc …
accurately model the integral quality monitoring (IQM) system® to be used in the BEAMnrc …
Monte Carlo Simulation of the Gamma-Ray Transmissions for the newly Designed Shielding Blocks used in Radiotherapy
N Yavuzkanat, HBS Kürem - Çanakkale Onsekiz Mart Üniversitesi …, 2020 - dergipark.org.tr
Radiotherapy is one of the most important treatment methods of cancer, which is the
worldwide disease nowa-days. It is essential to protect the critical organs and healthy tissue …
worldwide disease nowa-days. It is essential to protect the critical organs and healthy tissue …
Impact of radiobiological models on the calculation of the therapeutic parameters of Grid therapy for breast cancer
Therapeutic advantages of Grid therapy have been demonstrated in several theoretical
studies using the standard linear-quadratic (LQ) model. However, the suitability of the LQ …
studies using the standard linear-quadratic (LQ) model. However, the suitability of the LQ …
O uso do código de Monte Carlo MCNP em teses e dissertações acadêmicas: Uma revisão bibliográfica
ALC Ávila - 2023 - repositorio.ufu.br
RESUMO O código MCNP é um código de transporte de partículas e é uma ferramenta
completa, que vem sido amplamente utilizada nos mais diversos trabalhos e pesquisas …
completa, que vem sido amplamente utilizada nos mais diversos trabalhos e pesquisas …