Minimum reporting standards should be expected for preclinical radiobiology irradiators and dosimetry in the published literature

F Trompier, LA DeWerd, Y Poirier… - … journal of radiation …, 2024 - Taylor & Francis
The cornerstones of science advancement are rigor in performing scientific research,
reproducibility of research findings and unbiased reporting of design and results of the …

RENEB intercomparisons applying the conventional Dicentric Chromosome Assay (DCA)

U Oestreicher, D Samaga, E Ainsbury… - … journal of radiation …, 2017 - Taylor & Francis
Purpose: Two quality controlled inter-laboratory exercises were organized within the EU
project 'Realizing the European Network of Biodosimetry (RENEB)'to further optimize the …

A general mechanistic model enables predictions of the biological effectiveness of different qualities of radiation

SJ McMahon, AL McNamara, J Schuemann… - Scientific reports, 2017 - nature.com
Predicting the responses of biological systems to ionising radiation is extremely challenging,
particularly when comparing X-rays and heavy charged particles, due to the uncertainty in …

The Mayo Clinic Florida microdosimetric kinetic model of clonogenic survival: application to various repair-competent rodent and human cell lines

A Parisi, CJ Beltran, KM Furutani - International Journal of Molecular …, 2022 - mdpi.com
The relative biological effectiveness (RBE) calculations used during the planning of ion
therapy treatments are generally based on the microdosimetric kinetic model (MKM) and the …

RENEB inter-laboratory comparison 2021: the cytokinesis-block micronucleus assay

A Vral, D Endesfelder, K Balázs… - Radiation …, 2023 - meridian.allenpress.com
The goal of the RENEB inter-laboratory comparison 2021 exercise was to simulate a large-
scale radiation accident involving a network of biodosimetry labs. Labs were required to …

Biodose Tools: an R shiny application for biological dosimetry

A Hernández, D Endesfelder, J Einbeck… - … Journal of Radiation …, 2023 - Taylor & Francis
Introduction In the event of a radiological accident or incident, the aim of biological dosimetry
is to convert the yield of a specific biomarker of exposure to ionizing radiation into an …

RENEB–Running the European Network of biological dosimetry and physical retrospective dosimetry

U Kulka, M Abend, E Ainsbury, C Badie… - … Journal of Radiation …, 2017 - Taylor & Francis
Purpose: A European network was initiated in 2012 by 23 partners from 16 European
countries with the aim to significantly increase individualized dose reconstruction in case of …

Minimum reporting standards should be expected for preclinical radiobiology irradiators and dosimetry in the published literature

Y Poirier, LA DeWerd, F Trompier… - Radiation …, 2023 - meridian.allenpress.com
Preclinical researchers have long acknowledged the critical need for accurate dosimetry in
the conduct of radiation-exposure studies involving living systems. Although radiation …

RENEB/EURADOS field exercise 2019: robust dose estimation under outdoor conditions based on the dicentric chromosome assay

D Endesfelder, U Oestreicher, U Kulka… - … Journal of Radiation …, 2021 - Taylor & Francis
Purpose Biological and/or physical assays for retrospective dosimetry are valuable tools to
recover the exposure situation and to aid medical decision making. To further validate and …

RENEB inter-laboratory comparison 2021: the dicentric chromosome assay

D Endesfelder, U Oestreicher, M Bucher… - Radiation …, 2023 - meridian.allenpress.com
After large-scale radiation accidents where many individuals are suspected to be exposed to
ionizing radiation, biological and physical retrospective dosimetry assays are important tools …