Orsiro cobalt-chromium sirolimus-eluting stent: present and future perspectives

JF Iglesias, M Roffi, S Degrauwe… - Expert review of …, 2017 - Taylor & Francis
Introduction: New-generation drug-eluting stents (DES) represent the current standard of
care in patients undergoing percutaneous coronary intervention (PCI). Biodegradable …

Importance of Short-Term Neointimal Coverage of Drug-Eluting Stents in the Duration of Dual Antiplatelet Therapy

J Fluder-Wlodarczyk, S Pawłowski, PJ Chuchra… - Journal of Clinical …, 2024 - mdpi.com
Dual antiplatelet therapy (DAPT) is mandatory after percutaneous coronary intervention
(PCI) with drug-eluting stent (DES) implantation, but optimal DAPT duration remains a topic …

Current state of bioabsorbable polymer-coated drug-eluting stents

A Akinapelli, JP Chen, K Roy… - Current cardiology …, 2017 - ingentaconnect.com
Drug-eluting stents (DES) have been shown to significantly reduce clinical and angiographic
restenosis compared to bare metal stents (BMS). The polymer coatings on DES elute …

48-Month Clinical Outcomes and Prognostic Factors in an All-Comers Population with Acute Coronary Syndrome and Chronic Coronary Syndrome Undergoing …

M Tyczynski, A Kern, P Buller, RJ Gil, J Bil - Journal of Personalized …, 2023 - mdpi.com
We characterized the performance as well as safety of a second-generation thin-strut
sirolimus-eluting stent with a biodegradable polymer, Alex Plus (Balton, Poland), deployed …

[HTML][HTML] Preferable vascular healing of ultrathin strut biodegradable-polymer sirolimus-eluting stents in patients with acute coronary syndrome

A Kawamura, Y Egami, S Kawanami, H Sugae… - Cardiovascular …, 2022 - Springer
This study aimed to compare the strut coverage between Orsiro ultrathin struts
biodegradable polymer sirolimus-eluting stents (O-SES) and Xience thin struts durable …

Three-month evaluation of strut healing using a novel optical coherence tomography analytical method following bioresorbable polymer everolimus-eluting stent …

B Vesga, H Hernandez, M Moncada… - Coronary Artery …, 2017 - journals.lww.com
Aims Bioresorbable polymer drug-eluting stent technologies have been considered to have
the potential to enhance vascular healing by reducing polymer exposure to the vessel wall …

The BIOFLOW-III Italian Satellite Registry: 18-month results of the Orsiro stent in an all-comer high-risk population

AL Bartorelli, F Versaci, C Briguori… - Journal of …, 2019 - journals.lww.com
Aims We aimed to corroborate clinical evidence on the safety and efficacy of the ultrathin-
strut biodegradable-polymer sirolimus-eluting Orsiro stent in an all-comer population …

Early-and middle-phase arterial repair following bioresorbable-and durable-polymer drug-eluting stent implantation: An angioscopic study

T Ishihara, T Tsujimura, S Okuno, O Iida, M Asai… - International Journal of …, 2019 - Elsevier
Background Bioresorbable-polymer drug-eluting stent (BP-DES) demonstrates comparable
clinical outcomes compared to durable-polymer drug-eluting stent (DP-DES). However …

Neoatherosclerosis after Drug‐Eluting Stent Implantation: Roles and Mechanisms

Y Cui, Y Liu, F Zhao, D Shi… - Oxidative Medicine and …, 2016 - Wiley Online Library
In‐stent neoatherosclerosis (NA), characterized by a relatively thin fibrous cap and large
volume of yellow‐lipid accumulation after drug‐eluting stents (DES) implantation, has …

Vascular response to percutaneous coronary intervention with biodegradable-polymer vs. new-generation durable-polymer drug-eluting stents: a meta-analysis of …

S Cassese, E Xhepa, G Ndrepepa… - European Heart …, 2018 - academic.oup.com
Aims Whether biodegradable-polymer drug-eluting stents (BP-DES) induce a vascular
response at follow-up more favourable than that of new-generation durable-polymer drug …