[HTML][HTML] Real-time intrafraction motion monitoring in external beam radiotherapy

J Bertholet, A Knopf, B Eiben… - Physics in medicine …, 2019 - iopscience.iop.org
Radiotherapy (RT) aims to deliver a spatially conformal dose of radiation to tumours while
maximizing the dose sparing to healthy tissues. However, the internal patient anatomy is …

MRI-linear accelerator radiotherapy systems

GP Liney, B Whelan, B Oborn, M Barton, P Keall - Clinical Oncology, 2018 - Elsevier
The desire to utilise soft-tissue image guidance at the time of radiation treatment has led to
the development of several hybrid magnetic resonance imaging (MRI) linear accelerators …

Multiplexed imaging for diagnosis and therapy

K Heinzmann, LM Carter, JS Lewis… - Nature Biomedical …, 2017 - nature.com
Complex molecular and metabolic phenotypes depict cancers as a constellation of different
diseases with common themes. Precision imaging of such phenotypes requires flexible and …

Future of medical physics: real‐time MRI‐guided proton therapy

BM Oborn, S Dowdell, PE Metcalfe, S Crozier… - Medical …, 2017 - Wiley Online Library
With the recent clinical implementation of real‐time MRI‐guided x‐ray beam therapy
(MRXT), attention is turning to the concept of combining real‐time MRI guidance with proton …

Magnetic resonance imaging–guided radiation therapy: a short strengths, weaknesses, opportunities, and threats analysis

M van Herk, A McWilliam, M Dubec… - International Journal of …, 2018 - Elsevier
A number of magnetic resonance (MR)-guided radiation therapy devices are under
development, and the ViewRay system (ViewRay, Oakwood Village, OH), combining 3 …

[HTML][HTML] MRI-guided lung SBRT: present and future developments

MJ Menten, A Wetscherek, MF Fast - Physica Medica, 2017 - Elsevier
Stereotactic body radiotherapy (SBRT) is rapidly becoming an alternative to surgery for the
treatment of early-stage non-small cell lung cancer patients. Lung SBRT is administered in a …

[HTML][HTML] Reference dosimetry in MRI-linacs: evaluation of available protocols and data to establish a Code of Practice

J De Pooter, I Billas, L de Prez, S Duane… - Physics in Medicine …, 2021 - iopscience.iop.org
With the rapid increase in clinical treatments with MRI-linacs, a consistent, harmonized and
sustainable ground for reference dosimetry in MRI-linacs is needed. Specific for reference …

Relative dosimetry with an MR‐linac: response of ion chambers, diamond, and diode detectors for off‐axis, depth dose, and output factor measurements

DJ O'Brien, J Dolan, S Pencea, N Schupp… - Medical …, 2018 - Wiley Online Library
Purpose The purpose of this study was to acquire beam data for an MR‐linac, with and
without a 1.5 T magnetic field, by using a variety of commercially available detectors to …

Cross‐modality deep learning: contouring of MRI data from annotated CT data only

JP Kieselmann, CD Fuller… - Medical …, 2021 - Wiley Online Library
Purpose Online adaptive radiotherapy would greatly benefit from the development of
reliable auto‐segmentation algorithms for organs‐at‐risk and radiation targets. Current …

Magnetic field induced dose effects in radiation therapy using MR‐linacs

CY Huang, B Yang, WW Lam, H Geng… - Medical …, 2023 - Wiley Online Library
MR‐guided radiotherapy (MRgRT) is one of the most significant advances in radiotherapy in
recent years. The hybrid systems were designed to visualize patient anatomical and …