Fundamental noise limits and sensitivity of piezoelectrically driven magnetoelastic cantilevers
P Durdaut, E Rubiola, JM Friedt… - Journal of …, 2020 - ieeexplore.ieee.org
Magnetoelastic sensors for the detection of low-frequency and low-amplitude magnetic
fields are in the focus of research for more than 30 years. In order to minimize the limit of …
fields are in the focus of research for more than 30 years. In order to minimize the limit of …
High dynamic range AFM cantilever with a collocated piezoelectric actuator-sensor pair
We present a novel approach to fundamentally eliminate electrical feedthrough (cross-talk)
signal in self-sensing piezoelectric microcantilevers, used in dynamic mode atomic force …
signal in self-sensing piezoelectric microcantilevers, used in dynamic mode atomic force …
Simultaneous tip force and displacement sensing for AFM cantilevers with on-chip actuation: Design and characterization for off-resonance tapping mode
The use of integrated on-chip actuation simplifies the identification of a cantilever
resonance, can improve imaging speed, and enables the use of smaller cantilevers, which is …
resonance, can improve imaging speed, and enables the use of smaller cantilevers, which is …
Design, fabrication, and characterization of a piezoelectric AFM cantilever array
Atomic force microscope (AFM) is a powerful instrument, which has been successfully
employed in a myriad of applications from imaging to lithography, over the last decades …
employed in a myriad of applications from imaging to lithography, over the last decades …
FPGA-based characterization and Q-control of an active AFM cantilever
The slow transient response of Si cantilevers oscillating at resonance is a significant limiting
factor to achieving higher scan rates in tapping-mode atomic force microscopy (TM-AFM) …
factor to achieving higher scan rates in tapping-mode atomic force microscopy (TM-AFM) …
Recent Progress in Self-sensing Probe Technology in Atomic Force Microscope
K Xu, C Ji, F Wei, Z Zhai - Current Nanoscience, 2021 - ingentaconnect.com
The imaging speed of atomic force microscope (AFM) is limited by the cantilever mechanical
bandwidth, which can be increased by reducing the size of the cantilever. However, the …
bandwidth, which can be increased by reducing the size of the cantilever. However, the …
[PDF][PDF] Active Cantilever With Integrated Actuation and Sensing For Use in Off-Resonance Tapping AFM
NFS de Bem - 2023 - nova.newcastle.edu.au
I would like to thank my fianceé Bec for speaking words of affirmation and love to help me
finish this season. She is one of the most loving, kind souls I know. I love you very much. I …
finish this season. She is one of the most loving, kind souls I know. I love you very much. I …
[PDF][PDF] Fundamental Noise Limits and Sensitivity of Piezoelectrically Driven Magnetoelastic Cantilevers
PDM Cantilevers - jmfriedt.free.fr
Magnetoelastic sensors for the detection of lowfrequency and low-amplitude magnetic fields
are in the focus of research for more than 30 years. In order to minimize the limit of detection …
are in the focus of research for more than 30 years. In order to minimize the limit of detection …
Phase Sensitivity and Phase Noise of Cantilever-Type Magnetoelastic Sensors Based on the E Effect
Magnetoelastic sensors for the detection of low-frequency and low-amplitude magnetic
fields are in the focus of research since more than 30 years. In order to minimize the limit of …
fields are in the focus of research since more than 30 years. In order to minimize the limit of …