Improved dead-time correction for PET scanners: application to small-animal PET

E Vicente, JL Herraiz, S España… - Physics in Medicine …, 2013 - iopscience.iop.org
Pile-up and dead-time are two main causes of nonlinearity in the response of a PET scanner
as a function of activity in the field of view (FOV). For a given scanner and acquisition …

[PDF][PDF] Simulaciones Monte Carlo para Radioterapia Intraoperatoria con haces de electrones

EH Muelas - Universidad Complutense de Madrid, 2013 - core.ac.uk
Conocer la distribución de dosis en un paciente o maniquí es de gran importanciapara
poder determinar la eficacia de un tratamiento de radioterapia y también para evaluar los …

[PDF][PDF] Caractérisation, optimisation et simulation des performances d'un TEP-TDM numérique

J Salvadori - 2020 - theses.fr
La tomographie par émission de positons (TEP) est aujourd'hui la modalité d'imagerie
fonctionnelle la plus sensible pour étudier les interactions moléculaires dans le corps …

Improving reconstruction of dynamic PET imaging by utilizing temporal coherence and pharmacokinetics

X Cheng - 2015 - mediatum.ub.tum.de
Dynamic PET images suffer from limited reconstruction quality, affecting physiological
quantification and clinical diagnosis. This thesis utilizes temporal coherence and tracer …

Use of perfusion PET/CT imaging to assess cardiac function and repair in murine diabetic cardiac models and subsequent refinement and validation of predictive in …

A Alenezi - 2022 - orca.cardiff.ac.uk
Micro-positron emission tomography (micro-PET) imaging is a powerful imaging modality in
cardiovascular studies for the assessment of mice cardiac function in-vivo. This modality …

[PDF][PDF] Positron range and prompt gamma modeling in PET imaging

J Cal González - 2015 - docta.ucm.es
In last chapter we have studied positron range distributions for some common radionuclides
in PET imaging. The most widely used radionuclide and imaging agent is of course 18F …

[PDF][PDF] Positron range and prompt gamma modeling in PET imaging

JC González - 2014 - docta.ucm.es
In last chapter we have studied positron range distributions for some common radionuclides
in PET imaging. The most widely used radionuclide and imaging agent is of course 18F …

Simulaciones Monte Carlo para radioterapia intraoperatoria con haces de electrones

E Herranz Muelas - 2018 - docta.ucm.es
Conocer la distribución de dosis en un paciente o maniquí es de gran importanciapara
poder determinar la eficacia de un tratamiento de radioterapia y también para evaluar los …

[引用][C] Improving Reconstruction of Dynamic PET Imaging by Utilizing Temporal Coherence and Pharmacokinetics

LDC Tsoumpas