A systematic review of advanced sensor technologies for non-destructive testing and structural health monitoring
S Hassani, U Dackermann - Sensors, 2023 - mdpi.com
This paper reviews recent advances in sensor technologies for non-destructive testing
(NDT) and structural health monitoring (SHM) of civil structures. The article is motivated by …
(NDT) and structural health monitoring (SHM) of civil structures. The article is motivated by …
The state of the art in structural health monitoring of cable-stayed bridges
H Li, J Ou - Journal of Civil Structural Health Monitoring, 2016 - Springer
Cable-stayed bridges are a type of long-span bridges that have been extensively
constructed throughout the world. However, cable-stayed bridges suffer from a variety of …
constructed throughout the world. However, cable-stayed bridges suffer from a variety of …
Toward data anomaly detection for automated structural health monitoring: Exploiting generative adversarial nets and autoencoders
J Mao, H Wang, BF Spencer Jr - Structural Health Monitoring, 2021 - journals.sagepub.com
Damage detection is one of the most important tasks for structural health monitoring of civil
infrastructure. Before a damage detection algorithm can be applied, the integrity of the data …
infrastructure. Before a damage detection algorithm can be applied, the integrity of the data …
Probabilistic framework with bayesian optimization for predicting typhoon-induced dynamic responses of a long-span bridge
The long-span bridge, characterized by slenderness and flexibility, is particularly sensitive to
wind action. Extreme wind events, including typhoons and hurricanes, will threaten the …
wind action. Extreme wind events, including typhoons and hurricanes, will threaten the …
Optimum design of viscous inerter damper targeting multi-mode vibration mitigation of stay cables
Installation of transverse dampers near the cable-deck anchorage is a commonly used
method for the vibration mitigation of stay cables. Recent studies have demonstrated that the …
method for the vibration mitigation of stay cables. Recent studies have demonstrated that the …
Long-term monitoring of wind field characteristics and dynamic response of a long-span suspension bridge in complex terrain
Long-term monitoring data of wind velocities and accelerations on the Hardanger Bridge are
used to investigate the relationship between the wind-loading and response processes. The …
used to investigate the relationship between the wind-loading and response processes. The …
[HTML][HTML] Full long-term buffeting analysis of suspension bridges using Gaussian process surrogate modelling and importance sampling Monte Carlo simulations
DF Castellon, A Fenerci, ØW Petersen… - Reliability Engineering & …, 2023 - Elsevier
Recent findings from full-scale measurements campaigns and analytical investigations of
the design buffeting response of long-span bridges suggest that the assumptions adopted in …
the design buffeting response of long-span bridges suggest that the assumptions adopted in …
Efficient simulation of fully non-stationary random wind field based on reduced 2D hermite interpolation
The spectral representation method (SRM) has been widely used to simulate stationary or
non-stationary wind fields for engineering structures. Although several attempts have been …
non-stationary wind fields for engineering structures. Although several attempts have been …
Shake table test on transverse steel damper seismic system for long span cable-stayed bridges
In current transverse seismic design of long span cable-stayed bridges, the conventional
transverse fixed system (TFS) is usually adopted. This strategy inevitably increases seismic …
transverse fixed system (TFS) is usually adopted. This strategy inevitably increases seismic …
Cause investigation of high-mode vortex-induced vibration in a long-span suspension bridge
A significant vortex-induced vibration (VIV) was observed in a suspension bridge under a
wind velocity of approximately 6 and 7 m/s, and with a maximum amplitude that exceeded …
wind velocity of approximately 6 and 7 m/s, and with a maximum amplitude that exceeded …