Parallel MR imaging: a user's guide

JF Glockner, HH Hu, DW Stanley, L Angelos, K King - Radiographics, 2005 - pubs.rsna.org
Parallel imaging is a recently developed family of techniques that take advantage of the
spatial information inherent in phased-array radiofrequency coils to reduce acquisition times …

Massively parallel MRI detector arrays

B Keil, LL Wald - Journal of magnetic resonance, 2013 - Elsevier
Originally proposed as a method to increase sensitivity by extending the locally high-
sensitivity of small surface coil elements to larger areas via reception, the term parallel …

Coil compression for accelerated imaging with Cartesian sampling

T Zhang, JM Pauly, SS Vasanawala… - Magnetic resonance in …, 2013 - Wiley Online Library
MRI using receiver arrays with many coil elements can provide high signal‐to‐noise ratio
and increase parallel imaging acceleration. At the same time, the growing number of …

32‐channel 3 Tesla receive‐only phased‐array head coil with soccer‐ball element geometry

GC Wiggins, C Triantafyllou, A Potthast… - … in Medicine: An …, 2006 - Wiley Online Library
Abstract A 32‐channel 3T receive‐only phased‐array head coil was developed for human
brain imaging. The helmet‐shaped array was designed to closely fit the head with individual …

96‐Channel receive‐only head coil for 3 Tesla: design optimization and evaluation

GC Wiggins, JR Polimeni, A Potthast… - … in Medicine: An …, 2009 - Wiley Online Library
The benefits and challenges of highly parallel array coils for head imaging were investigated
through the development of a 3T receive‐only phased‐array head coil with 96 receive …

Array compression for MRI with large coil arrays

M Buehrer, KP Pruessmann… - … in Medicine: An …, 2007 - Wiley Online Library
Arrays with large numbers of independent coil elements are becoming increasingly
available as they provide increased signal‐to‐noise ratios (SNRs) and improved parallel …

Practical approaches to the evaluation of signal‐to‐noise ratio performance with parallel imaging: application with cardiac imaging and a 32‐channel cardiac coil

SB Reeder, BJ Wintersperger, O Dietrich… - … in Medicine: An …, 2005 - Wiley Online Library
In this work, two practical methods for the measurement of signal‐to‐noise‐ratio (SNR)
performance in parallel imaging are described. Phantoms and human studies were …

An introduction to coil array design for parallel MRI

MA Ohliger, DK Sodickson - NMR in Biomedicine: An …, 2006 - Wiley Online Library
The basic principles of radiofrequency coil array design for parallel MRI are described from
both theoretical and practical perspectives. Because parallel MRI techniques rely on coil …

Whole-body MR imaging in the German National Cohort: rationale, design, and technical background

F Bamberg, HU Kauczor, S Weckbach, CL Schlett… - Radiology, 2015 - pubs.rsna.org
Purpose To detail the rationale, design, and future perspective of implementing whole-body
magnetic resonance (MR) imaging in the German National Cohort, a large multicentric …

Advances in 4D medical imaging and 4D radiation therapy

G Li, D Citrin, K Camphausen… - … in cancer research …, 2008 - journals.sagepub.com
This paper reviews recent advances in 4D medical imaging (4DMI) and 4D radiation therapy
(4DRT), which study, characterize, and minimize patient motion during the processes of …