Experimental and numerical investigation of punching behavior of two-way RC slab with different opening locations and sizes strengthened with CFRP strip
Flat slabs are widely used due to their advantages. However, punching collapse is a
situation that should not be ignored during the design as a risk in this type of slab. The …
situation that should not be ignored during the design as a risk in this type of slab. The …
Punching performance of flat slabs with openings accounting for the influence of moment transfer and shear reinforcement
JB dos Santos, G de Sales Melo, MF Ruiz - Engineering Structures, 2024 - Elsevier
The arrangement of openings adjacent or near to slab-column connections is very common
practice in flat slab design due to a number of advantages for technical installations. Such …
practice in flat slab design due to a number of advantages for technical installations. Such …
Enhancement of the punching shear verification of slabs with openings
JB dos Santos, A Muttoni, GS de Melo - Structural Concrete, 2023 - Wiley Online Library
Openings in flat slabs near to columns are often needed to supply the building with utilities.
The presence of these openings can lead to a decrease of the punching resistance which is …
The presence of these openings can lead to a decrease of the punching resistance which is …
Effect of shape, number, and location of openings on punching shear capacity of flat slabs
E Yooprasertchai, Y Tiawilai, T Wittayawanitchai… - Buildings, 2021 - mdpi.com
Experimental evidence have proved that punching shear capacity of flat slabs deteriorate
with the presence of openings located within the critical perimeter around columns. It is …
with the presence of openings located within the critical perimeter around columns. It is …
Investigating punching shear in slabs with unbalanced moments and openings
JB Santos, RM Souza, GS Melo, RB Gomes - Engineering Structures, 2024 - Elsevier
The impact of openings and moment transfer on punching shear resistance was investigated
by conducting tests on nine interior slab-column connections measuring 2,400 mm square …
by conducting tests on nine interior slab-column connections measuring 2,400 mm square …
Punching behaviour of two-way RC slabs having different multiple opening locations and sizes strengthened with TRM
Flat slabs have been widely used to allow the larger interior areas to be created in
architectural plans, reduce the height of the building by allowing more story heights, and …
architectural plans, reduce the height of the building by allowing more story heights, and …
Numerical analysis on flat slabs with openings and SHEAR reinforcement
SR Costa, TF Pereira, SRC Ruas… - Structural …, 2024 - Wiley Online Library
The present study aims to parameterize the numerical models of flat slabs based on five
experimental prototypes developed previously. The analyzed slabs had dimensions of 1800 …
experimental prototypes developed previously. The analyzed slabs had dimensions of 1800 …
[HTML][HTML] Experimental and numerical investigation of the behavior of self-curing RC flat slabs
Self-curing concrete is one of the most notable enhancements in modern concrete
technology. The study presents experimental and numerical investigations conducted to …
technology. The study presents experimental and numerical investigations conducted to …
Nonlinear analysis of the impact of openings on punching shear strength
PHSM Vieira, RS Díaz, MG Marques… - Structural …, 2023 - Wiley Online Library
Reinforced concrete flat slab projects usually require openings close to the columns for
electrical and hydraulic installations. Since such openings reduce the punching shear of …
electrical and hydraulic installations. Since such openings reduce the punching shear of …
Low velocity impact response of reinforced concrete flat slabs
WS Abdulsahib, MS Abduljabbar… - The Open Civil …, 2023 - Elsevier
Background Dimensions of the reference concrete slab are 1950x1950x100 mm subjected
to drop-weight impact loading. Objective a comprehensive parametric study was performed …
to drop-weight impact loading. Objective a comprehensive parametric study was performed …