Seismic failure risk assessment of post electrical equipment on supporting structures

C He, L Jiang, L Jiang - IEEE Transactions on Power Delivery, 2023 - ieeexplore.ieee.org
To assess the seismic failure risk of post electrical equipment, an assessment method
considering different sorts of uncertainty of the post electrical equipment was proposed. The …

A rapid seismic fragility and risk analysis of electrical substation equipment considering modeling uncertainties

A Delaviz, HE Estekanchi - Engineering Structures, 2023 - Elsevier
This study aims to evaluate the influences of modeling-related uncertainties on the seismic
response and fragility function of the four vulnerable components of electrical substation …

Considering seismic interaction effects in designing steel supporting structure for surge arrester

S Li, HH Tsang, Y Cheng, Z Lu - Journal of Constructional Steel Research, 2017 - Elsevier
Porcelain surge arrester is common in electrical substation and is vulnerable in
earthquakes. In most cases, surge arrester needs to be mounted on the top of a steel …

Seismic testing and modeling of cylindrical electrical equipment with GFRP composite insulators

S Li, HH Tsang, Y Cheng, Z Lu - Composite Structures, 2018 - Elsevier
Glass fiber reinforced polymer (GFRP) composite is a desirable alternative to porcelain for
insulators of cylindrical electrical equipment in electrical substation. However, mechanical …

Influence of lumped mass and rotary inertia on seismic isolated post equipment

Q Xie, G Shi, Y Liu - Journal of Constructional Steel Research, 2022 - Elsevier
This paper addresses a need to lessen the effects of seismic activity on heavy functional
components installed on the top of post electrical equipment. A theoretical model was …

Seismic performance evaluation and improvement of ultra-high voltage wall bushing-valve hall system

C He, Q Xie, Z Yang, S Xue - Journal of Constructional Steel Research, 2019 - Elsevier
To evaluate and improve the seismic performance of a±800 kV ultra-high voltage (UHV) wall
bushing-valve hall system, a finite element model of the system was established. Sixteen …

Seismic terminal displacement of UHV post electrical equipment considering flange rotational stiffness

C He, Q Xie, L Jiang, L Jiang - Journal of Constructional Steel Research, 2021 - Elsevier
The displacement at the terminals of ultra-high-voltage (UHV) post electrical equipment is a
critical parameter in the seismic design of flexible conductor interconnected systems …

Study on seismic performance of porcelain pillar electrical equipment based on nonlinear dynamic theory

Y Xue, Y Cheng, Z Zhu, S Li, Z Liu… - Advances in Civil …, 2021 - Wiley Online Library
In order to consider the influence of nonlinear characteristics of porcelain pillar electrical
equipment on the dynamic response under seismic excitation, a theoretical analysis method …

Effects of sheds and cemented joints on seismic modelling of cylindrical porcelain electrical equipment in substations

S Li, HH Tsang, Y Cheng, Z Lu - Earthquakes and Structures, 2017 - koreascience.kr
Earthquake resilience of substations is essential for reliable and sustainable service of
electrical grids. The majority of substation equipment consists of cylindrical porcelain …

Finite element modeling and assessment of seismic response of electrical substations porcelain post insulators

MA Moustafa, KM Mosalam - Soil Dynamics and Earthquake Engineering, 2021 - Elsevier
The study presented in this paper focused on developing accurate computational finite
element (FE) model of electrical substations ceramic (porcelain) post insulators. The …