[HTML][HTML] Analysis on the crimping quality of overhead transmission line conductors considering equivalent cross-sectional stiffness
W Zhang, Y Liu, S Li, J Tang - AIP Advances, 2022 - pubs.aip.org
Approximately 58% of wire failures are caused by slippage and fracture of electrical
connectors, and the crimping quality analysis of connectors is based on equivalent cross …
connectors, and the crimping quality analysis of connectors is based on equivalent cross …
[HTML][HTML] Structural analysis of guyed steel telecommunication towers for radio antennas
MIR Oliveira, JGS Silva, PCGS Vellasco… - Journal of the Brazilian …, 2007 - SciELO Brasil
The usual structural analysis models for telecommunication and transmission steel tower
design tend to assume a simple truss behaviour where all the steel connections are …
design tend to assume a simple truss behaviour where all the steel connections are …
Discrete mechanical model for nonlinear dynamical analysis of planar guyed towers considering the unilateral contact of cables
FN Silva, FMA Silva - International Journal of Non-Linear Mechanics, 2024 - Elsevier
Towers are widely used for power line transmission, wind power plants, TV and radio
broadcasting, and telecommunications. To enhance their stability, cables are often …
broadcasting, and telecommunications. To enhance their stability, cables are often …
Structural assessment of a guyed mast through measurement of natural frequencies
G Saudi - Engineering Structures, 2014 - Elsevier
The structural investigation of 90 m. guyed communication tower was conducted using
experimental and numerical analyses. Being unused for more than one decade, the …
experimental and numerical analyses. Being unused for more than one decade, the …
Collapse of aluminum lattice mast as an effect of design and executive errors
Masts–as tall and slender structures–are usually analysed in an idealized scheme of a multi-
span beam supported on a central hinge and from several to over ten elastic supports …
span beam supported on a central hinge and from several to over ten elastic supports …
Three-dimensional analysis of the seismic response of guyed masts
GM Hensley, RH Plaut - Engineering structures, 2007 - Elsevier
The response of a 120 m-tall guyed mast to three-dimensional seismic excitation is analyzed
using the finite-element program ABAQUS. The Northridge earthquake and an amplified El …
using the finite-element program ABAQUS. The Northridge earthquake and an amplified El …
Mechanical modelling of stays under thermal loads
G Vairo, S Montassar - Mechanics, Models and Methods in Civil …, 2012 - Springer
This paper aims at investigating the effects of thermal loads on the elastic response of
cables in cable-stayed structures. Starting from a catenary-based approach, an analytical …
cables in cable-stayed structures. Starting from a catenary-based approach, an analytical …
A closed-form refined model of the cables' nonlinear response in cable-stayed structures
G Vairo - Mechanics of Advanced Materials and Structures, 2009 - Taylor & Francis
In this paper a refined second-order model for the analysis of the elastic response of cables
in cable-stayed structures is proposed. Starting from the exact catenary theory, the …
in cable-stayed structures is proposed. Starting from the exact catenary theory, the …
Mast behaviour analysis and peculiarities of numerical modelling
A Juozapaitis, R Kutas, D Jatulis - Journal of civil engineering and …, 2008 - Taylor & Francis
Straipsnyje aptariami stiebu kaip netiesiškai deformuojamu konstrukciniu sistemu
skaičiavimo ypatumai naudojant kompiuterinio projektavimo specializuotus programinius …
skaičiavimo ypatumai naudojant kompiuterinio projektavimo specializuotus programinius …