Mock circulatory loop applications for testing cardiovascular assist devices and in vitro studies
KW Xu, Q Gao, M Wan, K Zhang - Frontiers in Physiology, 2023 - frontiersin.org
The mock circulatory loop (MCL) is an in vitro experimental system that can provide
continuous pulsatile flows and simulate different physiological or pathological parameters of …
continuous pulsatile flows and simulate different physiological or pathological parameters of …
Mock circulatory loops used for testing cardiac assist devices: A review of computational and experimental models
F Cappon, T Wu, T Papaioannou, X Du… - … Journal of Artificial …, 2021 - journals.sagepub.com
Heart failure is a major health risk, and with limited availability of donor organs, there is an
increasing need for developing cardiac assist devices (CADs). Mock circulatory loops (MCL) …
increasing need for developing cardiac assist devices (CADs). Mock circulatory loops (MCL) …
A novel interface for hybrid mock circulations to evaluate ventricular assist devices
G Ochsner, R Amacher, A Amstutz… - IEEE transactions on …, 2012 - ieeexplore.ieee.org
This paper presents a novel mock circulation for the evaluation of ventricular assist devices
(VADs), which is based on a hardware-in-the-loop concept. A numerical model of the human …
(VADs), which is based on a hardware-in-the-loop concept. A numerical model of the human …
Evaluation of Physiological Control Systems for Rotary Left Ventricular Assist Devices: An In-Vitro Study
Rotary left ventricular assist devices (LVADs) show weaker response to preload and greater
response to afterload than the native heart. This may lead to ventricular suction or …
response to afterload than the native heart. This may lead to ventricular suction or …
A hybrid mock circulatory loop for fluid dynamic characterization of 3D anatomical phantoms
F Bardi, E Gasparotti, E Vignali… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
Goal: This work presents the development of a Hybrid Mock Circulatory Loop (HMCL) to
simulate hemodynamics at patient-specific level in terms of both 3D geometry and …
simulate hemodynamics at patient-specific level in terms of both 3D geometry and …
An advanced mock circulation loop for in vitro cardiovascular device evaluation
Controlled and repeatable in vitro evaluation of cardiovascular devices using a mock
circulation loop (MCL) is essential prior to in vivo or clinical trials. MCLs often consist of only …
circulation loop (MCL) is essential prior to in vivo or clinical trials. MCLs often consist of only …
Replication of the Frank-Starling response in a mock circulation loop
Mock circulation loops (MCLs) are used to evaluate cardiovascular devices prior to in-vivo
trials; however they lack the vital autoregulatory responses that occur in humans. This study …
trials; however they lack the vital autoregulatory responses that occur in humans. This study …
Starling‐like flow control of a left ventricular assist device: in vitro validation
The application of rotary left ventricular (LV) assist devices (LVAD s) is expanding from
bridge to transplant, to destination and bridge to recovery therapy. Conventional constant …
bridge to transplant, to destination and bridge to recovery therapy. Conventional constant …
[HTML][HTML] A cardiovascular simulator tailored for training and clinical uses
L Fresiello, G Ferrari, A Di Molfetta, K Zieliński… - Journal of Biomedical …, 2015 - Elsevier
Objective In the present work a cardiovascular simulator designed both for clinical and
training use is presented. Method The core of the simulator is a lumped parameter model of …
training use is presented. Method The core of the simulator is a lumped parameter model of …
A hybrid mock circulation loop for a total artificial heart
Rotary blood pumps are emerging as a viable technology for total artificial hearts, and the
development of physiological control algorithms is accelerated with new evaluation …
development of physiological control algorithms is accelerated with new evaluation …