[图书][B] The physics of modern brachytherapy for oncology

D Baltas, L Sakelliou, N Zamboglou - 2006 - taylorfrancis.com
Brachytherapy has become the modality of choice for several cancer localizations,
minimizing the possibility of unacceptable risks for healthy tissues and providing a more cost …

On the accuracy of monomer/polymer gel dosimetry in the proximity of a high-dose-rate 192Ir source

Y De Deene, N Reynaert… - Physics in Medicine & …, 2001 - iopscience.iop.org
The aim of this work was to investigate the applicability of MR-based polymer gel dosimetry
to measure the absorbed dose distribution at short distance from an iridium-192 …

In vivo thermoluminescence dosimetry dose verification of transperineal 192Ir high-dose-rate brachytherapy using CT-based planning for the treatment of prostate …

G Anagnostopoulos, D Baltas, A Geretschlaeger… - International Journal of …, 2003 - Elsevier
PURPOSE: To evaluate the potential of in vivo thermoluminescence dosimetry to estimate
the accuracy of dose delivery in conformal high-dose-rate brachytherapy of prostate cancer …

Beta versus gamma dosimetry close to Ir‐192 brachytherapy sources

D Baltas, P Karaiskos, P Papagiannis… - Medical …, 2001 - Wiley Online Library
The relative importance of the dose rate component owing to the beta spectrum emitted by
brachytherapy sources at the short radial distances of interest in intravascular and …

Thermoluminescent dosimetry of the selectSeed interstitial brachytherapy seed

G Anagnostopoulos, D Baltas, P Karaiskos… - Medical …, 2002 - Wiley Online Library
This work presents experimental dosimetry results for the new selectSeed prostate seed
design for use with the seedSelectron afterloading device, in accordance with the AAPM …

Monte Carlo and experimental high dose rate 192Ir brachytherapy dosimetry with microDiamond detectors

G Rossi, M Gainey, B Thomann, M Kollefrath… - … für Medizinische Physik, 2019 - Elsevier
The purpose of this study was to investigate the suitability of the microDiamond detector
(mDD) type 60019 (PTW-Freiburg, Germany) for radial dose function measurements with …

Transit dose of an Ir-192 high dose rate brachytherapy stepping source

TPY Wong, W Fernando, PN Johnston… - Physics in Medicine & …, 2001 - iopscience.iop.org
Clinical dosimetry for high dose rate (HDR) brachytherapy with a single stepping source
generally neglects the transit dose. This study investigates the effects of the transit dose in …

Limitations of the point and line source approximations for the determination of geometry factors around brachytherapy sources

P Karaiskos, L Sakelliou, P Sandilos… - Medical …, 2000 - Wiley Online Library
Geometry factors were calculated around commercially available pellets and elongated
brachytherapy sources taking into account their actual active core geometries. These …

A Monte Carlo investigation of the dosimetric characteristics of the VariSource high dose rate brachytherapy source

P Karaiskos, A Angelopoulos, P Baras… - Medical …, 1999 - Wiley Online Library
An analytical Monte Carlo simulation code, incorporating in detail source construction and
dimensions, was used to investigate the dosimetric characteristics of the VariSource high …

Experimental validation of dose calculation algorithms for the GliaSite™ RTS, a Novel liquid‐filled balloon brachytherapy applicator

JI Monroe, JF Dempsey, JA Dorton, S Mutic… - Medical …, 2001 - Wiley Online Library
This paper compares experimentally measured and calculated dose‐rate distributions for a
novel liquid‐filled brachytherapy balloon applicator (the GliaSite RTS), designed for the …