Connection of coupled buildings: A state-of-the-art review

R Doroudi, SHH Lavassani - Structures, 2021 - Elsevier
This paper presents a state-of-the-art review of significant studies published on coupled
buildings. The approach of connecting two adjacent buildings has been effectively applied …

Seismic control performance indices for magneto-rheological dampers considering simple soil-structure interaction

A Yanik - Soil Dynamics and Earthquake Engineering, 2020 - Elsevier
In this study, two instantaneous optimal control performance indices for seismic control of
structures incorporating magneto-rheological (MR) dampers are analytically defined. One of …

Pounding hazard mitigation between adjacent planar buildings using coupling strategy

M Abdeddaim, A Ounis, N Djedoui… - Journal of Civil Structural …, 2016 - Springer
The concept of coupled building is utilized to synchronize the response of two adjacent
buildings and reduce the minimum gap needed. This aims to avoid the pounding hazard …

[HTML][HTML] Retrofitting of a weaker building by coupling it to an adjacent stronger building using MR dampers

M Abdeddaim, A Ounis, MK Shrimali… - Structural Engineering …, 2017 - koreascience.kr
Among various retrofitting strategies, use of semi-active control for retrofitting a building
structure has gained momentum in recent years. One of the techniques for such retrofitting is …

Shake table tests of structures subject to pounding

V Crozet, I Politopoulos… - Earthquake Engineering & …, 2019 - Wiley Online Library
Pounding between adjacent structures during earthquakes may significantly modify their
response in terms of forces and displacements. In addition, it has a considerable influence …

Utilizing the adaptive control in mitigating the seismic response of adjacent buildings connected with MR dampers

OAS Al-Fahdawi, LR Barroso… - 2018 Annual American …, 2018 - ieeexplore.ieee.org
The mutual impacts between adjacent buildings caused large-scale damage during past
major earthquakes sparking interest in examining the reliability and effectiveness of various …

Response of a half-car model with optimal magnetorheological damper parameters

RS Prabakar, C Sujatha… - Journal of Vibration and …, 2016 - journals.sagepub.com
In this paper, control of the stationary response of a half-car model with a
magnetorheological (MR) damper moving over a random road is considered. The MR …

Small-scale MR damper: design, fabrication and evaluation

SV Sharma, G Hemalatha - Asian Journal of Civil Engineering, 2023 - Springer
The results of an experimental investigation on a developed small-scale MR damper for
seismic response reduction in buildings are presented in this article. The damper is intended …

Reduction of pounding between buildings using fuzzy controller

In this study, a FUZZY LOGIC CONTROLLER is employed to synchronize the response of
two adjacent buildings coupled with a magneto-rheological (MR) damper and also, to …

[HTML][HTML] Exact solution of free vibration of adjacent buildings interconnected by visco-elastic dampers

Y Chen, Z Ying, G Shen - Theoretical and Applied Mechanics Letters, 2020 - Elsevier
With consideration of a high-rise coupled building system, a flexible beams-based analytical
model is setup to characterize the dynamic behavior of the system. The general motion …