Medical physics challenges in clinical MR-guided radiotherapy
The integration of magnetic resonance imaging (MRI) for guidance in external beam
radiotherapy has faced significant research and development efforts in recent years. The …
radiotherapy has faced significant research and development efforts in recent years. The …
Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo‐based photon and electron external beam treatment planning
The Monte Carlo (MC) method has been shown through many research studies to calculate
accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient …
accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient …
Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions
W Schneider, T Bortfeld… - Physics in Medicine & …, 2000 - iopscience.iop.org
We describe a new method to convert CT numbers into mass density and elemental weights
of tissues required as input for dose calculations with Monte Carlo codes such as EGS4. As …
of tissues required as input for dose calculations with Monte Carlo codes such as EGS4. As …
Fifty years of Monte Carlo simulations for medical physics
DWO Rogers - Physics in Medicine & Biology, 2006 - iopscience.iop.org
Monte Carlo techniques have become ubiquitous in medical physics over the last 50 years
with a doubling of papers on the subject every 5 years between the first PMB paper in 1967 …
with a doubling of papers on the subject every 5 years between the first PMB paper in 1967 …
[PDF][PDF] DOSXYZnrc users manual
B Walters, I Kawrakow, DWO Rogers - Nrc Report Pirs, 2005 - nrc-cnrc.github.io
DOSXYZnrc is an EGSnrc-based Monte Carlo simulation code for calculating dose
distributions in a rectilinear voxel phantom and is based directly on the DOSXYZ code …
distributions in a rectilinear voxel phantom and is based directly on the DOSXYZ code …
Dose calculations for external photon beams in radiotherapy
A Ahnesjö, MM Aspradakis - Physics in Medicine & Biology, 1999 - iopscience.iop.org
Dose calculation methods for photon beams are reviewed in the context of radiation therapy
treatment planning. Following introductory summaries on photon beam characteristics and …
treatment planning. Following introductory summaries on photon beam characteristics and …
Monte Carlo simulations in radiotherapy dosimetry
P Andreo - Radiation Oncology, 2018 - Springer
Background The use of the Monte Carlo (MC) method in radiotherapy dosimetry has
increased almost exponentially in the last decades. Its widespread use in the field has …
increased almost exponentially in the last decades. Its widespread use in the field has …
DPM, a fast, accurate Monte Carlo code optimized for photon and electron radiotherapy treatment planning dose calculations
J Sempau, SJ Wilderman… - Physics in Medicine & …, 2000 - iopscience.iop.org
Abstract A new Monte Carlo (MC) algorithm, thedose planning method'(DPM), and its
associated computer program for simulating the transport of electrons and photons in …
associated computer program for simulating the transport of electrons and photons in …
Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm
M Fippel - Medical physics, 1999 - Wiley Online Library
A new Monte Carlo algorithm for 3D photon dose calculation in radiation therapy is
presented, which is based on the previously developed Voxel Monte Carlo (VMC) for …
presented, which is based on the previously developed Voxel Monte Carlo (VMC) for …
Dosimetric comparison of Acuros XB deterministic radiation transport method with Monte Carlo and model‐based convolution methods in heterogeneous media
T Han, JK Mikell, M Salehpour, F Mourtada - Medical Physics, 2011 - Wiley Online Library
Purpose: The deterministic Acuros XB (AXB) algorithm was recently implemented in the
Eclipse treatment planning system. The goal of this study was to compare AXB performance …
Eclipse treatment planning system. The goal of this study was to compare AXB performance …