On-site rapid diagnosis of intracranial hematoma using portable multi-slice microwave imaging system
AT Mobashsher, AM Abbosh - Scientific reports, 2016 - nature.com
Rapid, on-the-spot diagnostic and monitoring systems are vital for the survival of patients
with intracranial hematoma, as their conditions drastically deteriorate with time. To address …
with intracranial hematoma, as their conditions drastically deteriorate with time. To address …
3-D EM modeling of medical microwave imaging scenarios with controllable accuracy
Medical microwave imaging (MMWI) is a multidisciplinary task that requires precise
electromagnetic modeling of heterogeneous human tissues, solving non-linear and ill-posed …
electromagnetic modeling of heterogeneous human tissues, solving non-linear and ill-posed …
A multi-layered head phantom for microwave investigations of brain hemorrhages
M Otterskog, N Petrovic… - 2016 IEEE conference on …, 2016 - ieeexplore.ieee.org
A head phantom for microwave investigations is developed. It consists of a skull bone with
realistic dielectric properties of cancellous and cortical bone. The skull phantom is filled with …
realistic dielectric properties of cancellous and cortical bone. The skull phantom is filled with …
An LSTM Based Strategy for Data and Model Calibration in Subsurface Electromagnetic Imaging
Mismatch between measurements and model used inside the inversion scheme represent a
critical point in subsurface electromagnetic imaging. In this paper, a time-domain strategy …
critical point in subsurface electromagnetic imaging. In this paper, a time-domain strategy …
[PDF][PDF] Development of a Microwave Imaging System for Brain Injury
W Guo - 2023 - kclpure.kcl.ac.uk
This thesis presents the development of a microwave imaging (MWI) system for medical
diagnostics, focusing on the design and optimisation of the antenna system. MWI technology …
diagnostics, focusing on the design and optimisation of the antenna system. MWI technology …
Detection of Human Bodypart Abnormalities by Microwaves–A New Approach
We present modified antenna-like devices-applicators-for direct detection of internal
inhomogeneities such as breast tumours and brain haemorrhages, at a frequency about 1 …
inhomogeneities such as breast tumours and brain haemorrhages, at a frequency about 1 …
Microwave data inversion in hemorrhagic brain stroke imaging: A Newton-conjugate-gradient based approach in Lp Banach spaces
This paper concerns the problem of data inversion in microwave imaging for biomedical
applications. In particular, the integral equations of the inverse scattering problem are solved …
applications. In particular, the integral equations of the inverse scattering problem are solved …
Various diffraction effects and their importance for detection of inhomogeneites in human tissues
N Petrović, PO Risman - Facta Universitatis, Series …, 2020 - casopisi.junis.ni.ac.rs
Hitherto described microwave modalities for detection of internal inhomogeneities in human
tissues such as breasts and heads are by image reconstruction, requiring time-consuming …
tissues such as breasts and heads are by image reconstruction, requiring time-consuming …
Performance comparison of directional and omnidirectional ultra-wideband antennas in near-field microwave head imaging systems
AT Mobashsher, AM Abbosh - 2016 International Conference …, 2016 - ieeexplore.ieee.org
The objective of this paper is to study the effect and suitability of directionality in near-field
microwave head imaging system. To that end, the near-field performances of directional and …
microwave head imaging system. To that end, the near-field performances of directional and …
A nonlinear iterative inverse scattering procedure in Lp Banach spaces for microwave biomedical imaging
This paper presents a tomographic inverse scattering algorithm based on an iterative
regularization approach developed in L p Banach spaces. The proposed technique has …
regularization approach developed in L p Banach spaces. The proposed technique has …