A comprehensive review of auto-reclosing schemes in AC, DC, and hybrid (AC/DC) transmission lines
The integration of distributed generators has changed the paradigm of modern power
transmission systems. To cope with energy demands, electrical networks emphasize the …
transmission systems. To cope with energy demands, electrical networks emphasize the …
Power transmission lines: Worldwide research trends
F Alcayde-García, E Salmerón-Manzano, MA Montero… - Energies, 2022 - mdpi.com
The importance of the quality and continuity of electricity supply is increasingly evident given
the dependence of the world economy on its daily and instantaneous operation. In turn, the …
the dependence of the world economy on its daily and instantaneous operation. In turn, the …
Adaptive single-phase auto-reclosing scheme based on the moving average filter-quadrature signal generator for transmission lines with shunt reactors
X Xie, Z Huang, X Fan, T Tang - Electric Power Systems Research, 2023 - Elsevier
An adaptive single-phase auto-reclosing method based on the moving average filter (MAF)-
quadrature signal generator (QSG) is developed to determine secondary arc extinction time …
quadrature signal generator (QSG) is developed to determine secondary arc extinction time …
A high-speed adaptive single-phase reclosing technique based on local voltage phasors
F Zhalefar, MRD Zadeh… - IEEE Transactions on …, 2015 - ieeexplore.ieee.org
In this paper, a new adaptive single-phase reclosing method for high-voltage transmission
lines is proposed. This method employs local voltage magnitude and angle of the faulted …
lines is proposed. This method employs local voltage magnitude and angle of the faulted …
A noncommunication adaptive single-pole autoreclosure scheme based on the ACUSUM algorithm
M Khodadadi, MR Noori… - IEEE Transactions on …, 2013 - ieeexplore.ieee.org
In this paper, a new noncommunication-based adaptive single-pole autoreclosure (ASPAR)
scheme is proposed, by which the extinction of secondary arc can be detected rapidly, in 4 …
scheme is proposed, by which the extinction of secondary arc can be detected rapidly, in 4 …
Communication-aided high-speed adaptive single-phase reclosing
MRD Zadeh, R Rubeena - IEEE Transactions on Power …, 2012 - ieeexplore.ieee.org
A new communication-aided high-speed single-phase reclosing algorithm is proposed in
this paper for transposed transmission lines based on predicted and measured voltage of …
this paper for transposed transmission lines based on predicted and measured voltage of …
Comparison of secondary arcs for reclosing applications
This paper presents a comparison of secondary electric arcs behavior for reclosing
applications. The main objective of the paper is to show the differences in secondary arcs …
applications. The main objective of the paper is to show the differences in secondary arcs …
Phasor-based single-phase auto-reclosing scheme for non-compensated transmission lines
An approach to detect the secondary arc extinction is proposed here for single-phase auto-
reclosing of non-compensated transmission lines. It consists on the analysis of the line side …
reclosing of non-compensated transmission lines. It consists on the analysis of the line side …
Comparison between traditional single‐phase auto reclosing and adaptive technique based on harmonic content measurement
O Dias, MC Tavares - IET Generation, Transmission & …, 2017 - Wiley Online Library
This study presents the results of single‐phase auto reclosing technique tests, comparing
the performance of traditional procedure and fast adaptive procedure. The last is based on …
the performance of traditional procedure and fast adaptive procedure. The last is based on …
Adaptive single-pole autoreclosing concept with advanced DC fault current control for full-bridge MMC VSC systems
M Stumpe, P Ruffing, P Wagner… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
This paper presents an adaptive autoreclosing concept for HVDC transmission systems with
modular multilevel converters in full-bridge topology for single pole-to-ground faults. Since …
modular multilevel converters in full-bridge topology for single pole-to-ground faults. Since …