A New-Designed Biological Electric Shock Identification Method in Low-Voltage Distribution Network
G Yang, S Quan, W Gao - IEEE Transactions on Power Delivery, 2022 - ieeexplore.ieee.org
In general, residual current devices (RCDs) have problems such as protection dead-zone
and difficulty in threshold setting. A new method for identification of biological electric shock …
and difficulty in threshold setting. A new method for identification of biological electric shock …
Optimum design of substation grounding grid based on grid balancing parameters using genetic algorithm
Substation is the most vital part of electrical power system that should be operated
continually and safely. Ground grid is installed to help detecting ground faults and assure …
continually and safely. Ground grid is installed to help detecting ground faults and assure …
Evaluation of the optimum safety performance of the nuclear reactor compact grounding system under lightning strikes and ground fault
The electrical system of a nuclear reactor facility (NRF) must incorporate a grounding grid in
order to ensure it functions safely and reliably. Any disturbance in the electrical system …
order to ensure it functions safely and reliably. Any disturbance in the electrical system …
Analysis of the incidence of grounding with high resistivity against atmospheric discharges in the sub—Transmission line of 69KV San Rafael—Mulalo
A Mullo, V Javier, M Jiménez… - 2017 CHILEAN …, 2017 - ieeexplore.ieee.org
Electrical sub-transmission systems must ensure the reliability of the electrical system in the
event of sudden changes in voltage and current, especially when there are atmospheric …
event of sudden changes in voltage and current, especially when there are atmospheric …
On minimisation of earthing system touch voltages
V Vycital, M Ptacek, D Topolanek, P Toman - Energies, 2019 - mdpi.com
Finding cost efficient earthing system design with acceptable level of safety might be quite
tedious work. Thus, many earthing system engineers try to find the most suitable design …
tedious work. Thus, many earthing system engineers try to find the most suitable design …
Influencia de la Forma del Electrodo en la Resistencia Final de un Sistema de Puesta a Tierra.
W Duran - Investigación Tecnológica IST Central Técnico, 2019 - investigacionistct.ec
El presente trabajo analiza la influencia de la forma del electrodo en la resistencia final de
un sistema de puesta a tierra. Para el análisis se ha realizado un estudio analítico en el cual …
un sistema de puesta a tierra. Para el análisis se ha realizado un estudio analítico en el cual …
Optimización multiobjetivo en sistemas de puesta a tierra para subestaciones de potencia considerando la longitud de conductor.
DR Peñafiel Toledo - 2019 - dspace.ups.edu.ec
Los sistemas de puesta a tierra son de gran importancia dentro del campo de la ingeniería
eléctrica. Permite controlar los potenciales frente a corrientes de fuga que circular por el …
eléctrica. Permite controlar los potenciales frente a corrientes de fuga que circular por el …
[PDF][PDF] INDUCED VOLTAGE ON GAS PIPELINE DUE TO ALTERNATING CURRENT TOTAL INTERFERENCE OF FAULTED OVERHEAD TRANSMISSION LINE
A EL GAYAR - 2017 - eprints.utm.my
In locations where a buried gas pipeline (PL) shares the same right-of-way with a high
voltage overhead transmission line (TL), a relatively higher voltage than normally allowed …
voltage overhead transmission line (TL), a relatively higher voltage than normally allowed …