Comprehensive overview of low voltage ride through methods of grid integrated wind generator

OP Mahela, N Gupta, M Khosravy, N Patel - Ieee Access, 2019 - ieeexplore.ieee.org
The wind power generation is a rapidly growing grid integrated renewable energy (RE)
technology with an installed capacity of 539.291 GW. The capability of the wind energy …

Doubly-fed induction generator based wind turbines: A comprehensive review of fault ride-through strategies

JJ Justo, F Mwasilu, JW Jung - Renewable and sustainable energy reviews, 2015 - Elsevier
This paper presents an over-review of various strategies applied to enhance the fault ride-
through (FRT) capability of the doubly-fed induction generators (DFIGs) based wind turbines …

Transient stability analysis and enhancement of renewable energy conversion system during LVRT

X He, H Geng, R Li, BC Pal - IEEE Transactions on Sustainable …, 2019 - ieeexplore.ieee.org
Grid-connected renewable energy conversion systems (RECSs) are usually required by grid
codes to possess the low voltage ride through (LVRT) and reactive power support …

Grid-synchronization stability improvement of large scale wind farm during severe grid fault

SK Ma, H Geng, L Liu, G Yang… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
Loss of synchronization between wind farm and power grid during severe grid faults would
cause wind farm tripping. In this paper, the mechanism of grid-synchronization is uncovered …

LVRT capability of DFIG-based WECS under asymmetrical grid fault condition

H Geng, C Liu, G Yang - IEEE transactions on Industrial …, 2012 - ieeexplore.ieee.org
In this paper, the low-voltage ride-through (LVRT) capability of the doubly fed induction
generator (DFIG)-based wind energy conversion system in the asymmetrical grid fault …

Small signal dynamics of DFIG-based wind turbines during riding through symmetrical faults in weak AC grid

J Hu, B Wang, W Wang, H Tang… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
Instability issues of the grid-connected doubly fed induction generator (DFIG) based wind
turbines (WTs) during low-voltage ride-through (LVRT) have got little attention yet. In this …

Challenges of integrating renewable energy sources to smart grids: A review

D Eltigani, S Masri - Renewable and Sustainable Energy Reviews, 2015 - Elsevier
The deep penetration of renewable energy sources is on the cutting edge of smart grid
vision. However, the variability and limited predictability of these sources have brought many …

Modeling of wind turbine generators for power system stability studies: A review

X He, H Geng, G Mu - Renewable and Sustainable Energy Reviews, 2021 - Elsevier
Wind power generation is making an increasingly significant contribution to global electricity
production. The high penetration of wind power greatly affects the stability of modern power …

Combined low voltage ride through and power smoothing control for DFIG/PMSG hybrid wind energy conversion system employing a SMES-based AC-DC unified …

JX Jin, RH Yang, RT Zhang, YJ Fan, Q Xie… - International Journal of …, 2021 - Elsevier
Abstract An Interline AC-DC unified power quality conditioner (UPQC) protection device is
proposed and designed based on superconducting magnetic energy storage (SMES) in this …

LVRT performance enhancement of DFIG-based wind farms by capacitive bridge-type fault current limiter

M Firouzi, GB Gharehpetian - IEEE Transactions on Sustainable …, 2017 - ieeexplore.ieee.org
Low voltage ride-through (LVRT) is one of the main requirements of the new grid codes for
integration of wind farms (WFs) to power system. In this paper, to enhance the LVRT …