End-to-end design of ingestible electronics
Ingestible electronics can potentially be used to track and treat gastrointestinal diseases in
real time. In the past decade, substantial improvements have been made to ingestible …
real time. In the past decade, substantial improvements have been made to ingestible …
Cloud-assisted industrial cyber-physical systems: An insight
X Yue, H Cai, H Yan, C Zou, K Zhou - Microprocessors and Microsystems, 2015 - Elsevier
The development of industrialization and information communication technology (ICT) has
deeply changed our way of life. In particular, with the emerging theory of “Industry 4.0”, the …
deeply changed our way of life. In particular, with the emerging theory of “Industry 4.0”, the …
Accelerated visual context classification on a low-power smartwatch
Data produced by wearable sensors is key in contexts such as performance enhancement
and training help for sports and fitness, continuous monitoring for aging people and for …
and training help for sports and fitness, continuous monitoring for aging people and for …
One Mbps 1 nJ/b 3.5–4 GHz fully integrated FM-UWB transmitter for WBAN applications
This paper introduces a fully integrated frequency-modulated ultra-wideband (UWB)
transmitter implemented in 130 nm CMOS technology. The 3.5-4 GHz band transmitter …
transmitter implemented in 130 nm CMOS technology. The 3.5-4 GHz band transmitter …
Neural Dielet: A 0.4 mm Battery-Less Crystal-Less Neural-Recording System on Die Achieving 1.6 cm Backscatter Range With 2 mm ×2 mm On-Chip Antenna
Miniaturization is essential in the design of wireless neural-recording systems. In recent
years, the battery in neural-recording systems can be eliminated by wireless power transfer …
years, the battery in neural-recording systems can be eliminated by wireless power transfer …
A millimeter-scale crystal-less MICS transceiver for insertable smart pills
This paper presents a millimeter-scale crystal-less wireless transceiver for volume-
constrained insertable pills. Operating in the 402-405 MHz medical implant communication …
constrained insertable pills. Operating in the 402-405 MHz medical implant communication …
A 0.55 V bandgap reference with a 59 ppm/° C temperature coefficient
R Nagulapalli, K Hayatleh, S Barker… - Journal of Circuits …, 2019 - World Scientific
This paper presents a novel low power, low voltage CMOS bandgap reference (BGR) that
overcomes the problems with the existing BJT-based reference circuits by using a MOS …
overcomes the problems with the existing BJT-based reference circuits by using a MOS …
Bio-WiTel: A low-power integrated wireless telemetry system for healthcare applications in 401–406 MHz band of MedRadio spectrum
This paper presents a low-power integrated wireless telemetry system (Bio-WiTel) for
healthcare applications in 401–406 MHz frequency band of medical device …
healthcare applications in 401–406 MHz frequency band of medical device …
A study on application of dielectric resonator antenna in implantable medical devices
Worldwide, a large number of patients are benefited every year due to technological
advancement in implantable medical devices (IMDs) such as in hyperthermia and bio …
advancement in implantable medical devices (IMDs) such as in hyperthermia and bio …
Evolution of biotelemetry in medical devices: from radio pills to mm-scale implants
V Valente - IEEE Transactions on Biomedical Circuits and …, 2022 - ieeexplore.ieee.org
The advent of semiconductor technology in the mid-20th century created unprecedented
opportunities to develop a new generation of small-scale wireless medical sensing devices …
opportunities to develop a new generation of small-scale wireless medical sensing devices …