Comparison and repeatability of keratometric and corneal power measurements obtained by Orbscan II, Pentacam, and Galilei corneal tomography systems

AZ Crawford, DV Patel, CNJ McGhee - American journal of ophthalmology, 2013 - Elsevier
PURPOSE: To assess the repeatability and comparability of corneal power and central
corneal thickness (CCT) measurements obtained using Orbscan II (Bausch & Lomb) …

Topography and tomography in the diagnosis of corneal ectasia

S Ramamurthy, JC Reddy, V Jhanji - Expert Review of …, 2015 - Taylor & Francis
For the modern day refractive surgeon, tomography has become an invaluable tool for
selection of patients for refractive surgery; in addition it is essential for the diagnosis and …

Comparison of central corneal thickness measurements using ultrasound pachymetry, ultrasound biomicroscopy, and the Artemis-2 VHF scanner in normal eyes

HM Al-Farhan, WM Al-Otaibi - Clinical ophthalmology, 2012 - Taylor & Francis
Purpose To compare the precision of central corneal thickness (CCT) measurements taken
with the handheld ultrasound pachymeter (USP), ultrasound biomicroscopy (UBM), and the …

[HTML][HTML] Comparison of corneal measurements in keratoconic eyes using rotating Scheimpflug camera and scanning-slit topography

M Naderan, S Shoar, M Naderan… - International journal …, 2015 - ncbi.nlm.nih.gov
AIM To compare the anterior segment measurements obtained by rotating Scheimpflug
camera (Pentacam) and Scanning-slit topography (Orbscan IIz) in keratoconic eyes …

Evaluation of corneal thickness using a Scheimpflug–Placido disk corneal analyzer and comparison with ultrasound pachymetry in eyes after laser in situ …

J Huang, W Lu, G Savini, L Hu, C Pan… - Journal of Cataract & …, 2013 - journals.lww.com
Purpose To evaluate the repeatability and reproducibility of corneal thickness
measurements in post-laser in situ keratomileusis (LASIK) eyes using a rotating Scheimpflug …

Repeatability of Scheimpflug-Placido camera in mild dry eye versus normal eyes according to the topographical position of the cornea

S Hwang, DS Kim, D Kim, EH Hong, YU Shin… - Scientific Reports, 2024 - nature.com
We aimed to investigate the repeatability of various corneal measurements according to
topographical location in the entire cornea measured by dual rotating Scheimpflug-Placido …

Comparison of anterior chamber depth measurements from the Galilei Dual Scheimpflug Analyzer with IOLMaster

RP Patel, RT Pandit - Journal of Ophthalmology, 2012 - Wiley Online Library
Purpose. To compare anterior chamber depth (ACD), representing the distance between the
anterior corneal surface and anterior lens surface measurements between the Galilei Dual …

Comparison of laser platform estimation and objective measurement of maximum ablation depth using Scheimpflug pachymetry in myopic femtosecond laser in situ …

JL Febbraro, H Picard, S Moran, A Grise-Dulac… - Cornea, 2020 - journals.lww.com
Purpose: To compare the preoperative estimation of maximum ablation depth provided by
the laser platform with objective measurement using Scheimpflug pachymetry in myopic …

Repeatability and comparability of corneal thickness measurements obtained from Dual Scheimpflug Analyzer and from ultrasonic pachymetry

ZN Al-Mohtaseb, L Wang, MP Weikert - Graefe's Archive for Clinical and …, 2013 - Springer
Background To assess the repeatability and comparability of central corneal thickness
(CCT) measurements obtained from the Galilei Dual Scheimpflug Analyzer (Galilei-DSA) …

Orbscan 3 versus Pentacam HR: evaluating the possible interchangeable use of various parameters

HM Gharieb, IS Othman, RS Elkitkat - Cornea, 2020 - journals.lww.com
Purpose: Many topography/tomography devices are available, and their interchangeable
use is frequently questioned. This study aimed to compare the analogous indices of Orbscan …