Turbulent jet modelling for hazardous area classification

R Benintendi - Journal of Loss Prevention in the Process Industries, 2010 - Elsevier
Hazardous area classification, as per EN 60079-10, is based on the explosive gas volume of
the clouds in which the average gas concentration is related to the Low Explosion Limit …

Underground gas pipeline explosion and fire: CFD based assessment of foreseeability

KB Mishra, KD Wehrstedt - Journal of natural gas science and engineering, 2015 - Elsevier
Scenarios of underground gas pipeline failure, crater formation, dispersion of gas, explosion
and subsequent fires are investigated with semi-empirical and with CFD (Computational …

Numerical modelling of gas dispersion using OpenFOAM

J Fiates, SSV Vianna - Process Safety and Environmental Protection, 2016 - Elsevier
In the current work the rhoReactingBuoyantFoam solver was customised for performing gas
leak and gas dispersion modelling. Using experimental data from gas leaks the proposed …

Ventilation theory and dispersion modelling applied to hazardous area classification

DM Webber, MJ Ivings, RC Santon - Journal of Loss prevention in the …, 2011 - Elsevier
Critical formulae given in the current Explosive Atmospheres Hazardous Area Classification
Standard IEC 60079-10-1 (2008)[BS EN 60079-10-1, 2009] to determine the expected gas …

Математическое моделирование трубопроводных сетей и систем каналов: методы, модели и алгоритмы

ВЕ Селезнев, ВВ Алешин, СН Прялов - 2014 - elibrary.ru
В монографии приводится подробное описание базовых методов численного
моделирования трубопроводных сетей и систем каналов с открытым руслом (рек) …

Flammable gas cloud build up in a ventilated enclosure

MJ Ivings, SE Gant, CJ Saunders, DJ Pocock - Journal of hazardous …, 2010 - Elsevier
Ventilation is frequently used as a means for preventing the build up of flammable or toxic
gases in enclosed spaces. The effectiveness of the ventilation often has to be considered as …

The classification of hazardous areas where explosive gas atmospheres may be present

R Tommasini - Safety science, 2013 - Elsevier
The classification of hazardous areas where explosive gas atmospheres may be present is
prescribed by European directives, international and national standards. This paper briefly …

Investigation of the ventilation flow in a gas turbine package enclosure

J Kowalski, F di Mare, S Theis… - 13 th European …, 2019 - euroturbo.eu
The ventilation flow of a gas turbine enclosure was investigated both experimentally and
numerically in a scaled test rig. Its gas turbine components were inactive and mainly …

[HTML][HTML] Numerical Study on Extent of Hazardous Area for Sonic Jet Release Using Equivalent Leak Diameter

승호최, 형권최 - Journal of the Korean Society of Hazard Mitigation, 2021 - j-kosham.or.kr
In this study, three-dimensional κ-ε turbulence numerical simulations were conducted to
analyze the extent of hazardous area for the sonic jet leakage of flammable gas …

International standards on explosive atmospheres: harmonization is a hard but necessary task

E Rangel, CA Sanguedo - Petroleum and Chemical Industry …, 2011 - ieeexplore.ieee.org
Professionals dealing with electrical installations in explosive atmospheres face a difficult