The role of Cor‐Knot in the future of cardiac surgery: A systematic review
I Jenkin, I Prachee, PA Sokal… - Journal of Cardiac …, 2020 - Wiley Online Library
Abstract Objective The Cor‐Knot automated fastener has been used to eliminate the need
for manual knot‐tying in cardiac valve surgery for over a decade. We review the current …
for manual knot‐tying in cardiac valve surgery for over a decade. We review the current …
What is the safety and efficacy of the use of automated fastener in heart valve surgery?
MY Salmasi, L Chien, P Hartley… - Journal of Cardiac …, 2019 - Wiley Online Library
Abstract Introduction Cor‐Knot automated fastener has been used as an adjunct in heart
valve surgery to eliminate the need for manual tying during valve implantation. Although …
valve surgery to eliminate the need for manual tying during valve implantation. Although …
Facilitating technologies in minimally invasive aortic valve replacement: a propensity score analysis
K Plestis, O Orlov, VN Shah, J Wong… - Interactive …, 2018 - academic.oup.com
OBJECTIVES Minimally invasive aortic valve replacement (MIAVR) can be technically
demanding and may lead to prolonged operative time. We evaluated the intraoperative and …
demanding and may lead to prolonged operative time. We evaluated the intraoperative and …
Incidence of valvular regurgitation and leaflet perforation by using automated titanium fasteners (CORKNOT®) in heart valve repair or replacement: less usual than …
F Sazzad, OZ Xian, A Ler, C Guohao, KG Swee… - Journal of …, 2021 - Springer
Background CORKNOT® facilitates a reduction in cardiopulmonary bypass (CPB) time,
aortic cross clamp (ACC) time and operative time, but reported to be associated with other …
aortic cross clamp (ACC) time and operative time, but reported to be associated with other …
Use of an automated suture fastening device in minimally invasive aortic valve replacement
TJ Beute, MD Oram, TM Schiller, M Goehler… - The Annals of thoracic …, 2018 - Elsevier
Background Minimally invasive aortic valve replacement (mAVR) is gaining clinical
acceptance; however, it is associated with increased operative times because of the limited …
acceptance; however, it is associated with increased operative times because of the limited …
Cor-Knot perforation of aortic valve leaflet
FA Baciewicz - The Annals of thoracic surgery, 2018 - annalsthoracicsurgery.org
1. Chan EKL, Andrade LEC. Clarification needed regarding antitopoisomerase I as a
biomarker for non-small cell lung cancer (letter). Ann Thorac Surg 2018; 106: 935. 2. Wu …
biomarker for non-small cell lung cancer (letter). Ann Thorac Surg 2018; 106: 935. 2. Wu …
Leaflet perforation by Cor-Knot automated fasteners: more usual than you think
HRC Biefer, A Weber, F Maisano… - The Annals of …, 2018 - annalsthoracicsurgery.org
1. Lameijer H, Crombach A. Aortic dissection during pregnancy or in the postpartum period:
it all starts with clinical recognition (letter). Ann Thorac Surg 2018; 105: 663. 2. Zhu JM, Ma …
it all starts with clinical recognition (letter). Ann Thorac Surg 2018; 105: 663. 2. Zhu JM, Ma …
Incidence, natural history, and factors associated with paravalvular leak following surgical aortic valve replacement
VN Shah, OI Orlov, CP Orlov, M Buckley… - …, 2019 - journals.sagepub.com
Objective: Our study investigates the incidence, cumulative incidence, natural history, and
factors associated with intraoperative paravalvular leak (PVL) and the development of a …
factors associated with intraoperative paravalvular leak (PVL) and the development of a …
Delayed metallic embolization of a Cor-knot fastener
HE Garrett Jr - The Thoracic and cardiovascular surgeon …, 2017 - thieme-connect.com
Background The Cor-Knot device is a titanium fastener which is widely used in cardiac valve
procedures. Adverse events associated with use of the device have been rare. Case …
procedures. Adverse events associated with use of the device have been rare. Case …
Prosthetic valve leaflet perforation resulting in critical aortic insufficiency: A rare late complication after use of Cor‐knot®
SP Patel, RJ Cubeddu, SE D'Orazio… - Journal of Cardiac …, 2022 - Wiley Online Library
The implementation of automatic fasteners such as the Cor‐knot® device (LSI Solutions,
Inc.) has revolutionized the field of minimally invasive valvular surgery. Nonetheless …
Inc.) has revolutionized the field of minimally invasive valvular surgery. Nonetheless …