Numerical models for lateral behaviour analysis of cold-formed steel framed walls: State of the art, evaluation and challenges
Cold-formed steel (CFS) shear walls are the primary lateral load resisting components in
lightweight steel framed (LSF) structures. The development of increasing complex LSF …
lightweight steel framed (LSF) structures. The development of increasing complex LSF …
[HTML][HTML] Review of the mechanical failure of non-combustible facade systems in fire
Fires involving the facade of a building are a modern and complex problem. Previous
reviews on fire safety of facades have addressed flammability and fire spread, but these are …
reviews on fire safety of facades have addressed flammability and fire spread, but these are …
Experimental investigation of post-fire mechanical properties of cold-formed steels
S Gunalan, M Mahendran - Thin-Walled Structures, 2014 - Elsevier
Cold-formed steel members are widely used in residential, industrial and commercial
buildings as primary load-bearing elements. During fire events, they will be exposed to …
buildings as primary load-bearing elements. During fire events, they will be exposed to …
Full-scale fire resistance tests of steel and plasterboard sheathed web-stiffened stud walls
Light gauge steel-framed (LSF) walls, commonly made with lipped channel studs and
gypsum plasterboard sheathing, are increasingly being used in low to mid-rise buildings …
gypsum plasterboard sheathing, are increasingly being used in low to mid-rise buildings …
Elevated temperature material properties of advanced high strength steel alloys
Abstract Advanced High-Strength Steels (AHSS) have high potential to be adopted in future
innovative infrastructure. However, the material properties of AHSS at elevated temperature …
innovative infrastructure. However, the material properties of AHSS at elevated temperature …
Fire performance of load bearing LSF wall systems made of low strength steel studs
AD Ariyanayagam, M Mahendran - Thin-Walled Structures, 2018 - Elsevier
Light gauge steel frame (LSF) walls are commonly used in single and two storey residential
and commercial buildings and modular based mid-rise building construction. They are lined …
and commercial buildings and modular based mid-rise building construction. They are lined …
Full-scale experiments of gypsum-sheathed cavity-insulated cold-formed steel walls under different fire conditions
W Chen, J Ye, Q Zhao, J Jiang - Journal of Constructional Steel Research, 2020 - Elsevier
Most previous fire experiments of cold-formed steel (CFS) walls focused on ISO 834 fire. The
corresponding results may not represent the actual fire performance of CFS walls in some …
corresponding results may not represent the actual fire performance of CFS walls in some …
Numerical study of LSF walls made of cold-formed steel hollow section studs in fire
Y Tao, M Mahendran, A Ariyanayagam - Thin-Walled Structures, 2021 - Elsevier
Cold-formed steel square and rectangular hollow section (SHS/RHS) studs are often used to
replace the conventional lipped channel section studs in light gauge steel frame (LSF) wall …
replace the conventional lipped channel section studs in light gauge steel frame (LSF) wall …
Numerical modelling and fire testing of gypsum plasterboard sheathed cold-formed steel walls
T Abeysiriwardena, M Mahendran - Thin-Walled Structures, 2022 - Elsevier
Gypsum plasterboards are used in Light-gauged Steel Framed (LSF) walls as the primary
fire-resistant material. In addition to thermal protection, they provide restraints to the cold …
fire-resistant material. In addition to thermal protection, they provide restraints to the cold …
Influence of cavity insulation on the fire resistance of light gauge steel framed walls
AD Ariyanayagam, M Mahendran - Construction and Building Materials, 2019 - Elsevier
Light gauge steel framed (LSF) walls are used in fire compartmentation to prevent the
spread of fire, smoke and toxic gases. The fire behavioural characteristics of non-load …
spread of fire, smoke and toxic gases. The fire behavioural characteristics of non-load …