Tissue mimicking materials for imaging and therapy phantoms: a review
CK McGarry, LJ Grattan, AM Ivory, F Leek… - Physics in Medicine …, 2020 - iopscience.iop.org
Tissue mimicking materials (TMMs), typically contained within phantoms, have been used
for many decades in both imaging and therapeutic applications. This review investigates the …
for many decades in both imaging and therapeutic applications. This review investigates the …
Ionizing radiation‐induced acoustics for radiotherapy and diagnostic radiology applications
Acoustic waves are induced via the thermoacoustic effect in objects exposed to a pulsed
beam of ionizing radiation. This phenomenon has interesting potential applications in both …
beam of ionizing radiation. This phenomenon has interesting potential applications in both …
Simulation and optimization of optical fiber irradiation with X-rays at different energies
A Meyer, D Lambert, A Morana, P Paillet, A Boukenter… - Radiation, 2023 - mdpi.com
Simple Summary We investigated the influence of modifying the voltage of an X-ray tube,
and therefore its photon energy spectrum, on the Total Ionizing Dose deposited in a single …
and therefore its photon energy spectrum, on the Total Ionizing Dose deposited in a single …
A review: photonic devices used for dosimetry in medical radiation
Numerous instruments such as ionization chambers, hand-held and pocket dosimeters of
various types, film badges, thermoluminescent dosimeters (TLDs) and optically stimulated …
various types, film badges, thermoluminescent dosimeters (TLDs) and optically stimulated …
Microfluidic synthesis of theranostic nanoparticles with near-infrared scintillation: toward next-generation dosimetry in X-ray-induced photodynamic therapy
M Isikawa, E Guidelli - ACS Applied Materials & Interfaces, 2021 - ACS Publications
We developed a microfluidic synthesis to grow GdF3: Eu theranostic scintillating
nanoparticles to simultaneously monitor the X-ray dose delivered to tumors during …
nanoparticles to simultaneously monitor the X-ray dose delivered to tumors during …
Analysis of the response of PVA-GTA Fricke-gel dosimeters with clinical magnetic resonance imaging
Fricke gel dosimeters produced with a matrix of Poly-vinyl alcohol (PVA) cross-linked with
glutaraldehyde (GTA) were analyzed with magnetic resonance imaging (MRI). Previous …
glutaraldehyde (GTA) were analyzed with magnetic resonance imaging (MRI). Previous …
Improvement on the performance of chemically cross-linked fricke methylthymol-blue radiochromic gel dosimeter by addition of dimethyl sulfoxide
The effect of free radical scavenger dimethyl sulfoxide (DMSO) on the performance of
transparent Fricke methylthymol blue dye (MTB)-polyvinyl alcohol (PVA)-chemical cross …
transparent Fricke methylthymol blue dye (MTB)-polyvinyl alcohol (PVA)-chemical cross …
Smart sensors for healthcare and medical applications
This special issue on “Smart Sensors for Healthcare and Medical Applications” focuses on
new sensing technologies, measurement techniques, and their applications in medicine and …
new sensing technologies, measurement techniques, and their applications in medicine and …
High optical stability of reusable radiochromic polyvinyl alcohol-iodine gel dosimeter for radiotherapy
In this study, a stable reusable radio-chromic gel dosimeter based on a polyvinyl alcohol-
sodium iodide complexes (PVA-NaI) and chemical cross-linking agent glutaraldehyde …
sodium iodide complexes (PVA-NaI) and chemical cross-linking agent glutaraldehyde …
Characterization of radiochromic poly (vinyl-alcohol)–glutaraldehyde Fricke gels for dosimetry in external x-ray radiation therapy
S Gallo, E Artuso, MG Brambilla… - Journal of Physics D …, 2019 - iopscience.iop.org
Quality assurance procedures required in modern radiotherapy would greatly benefit from
the development of tissue equivalent dosimeters able to render three-dimensional dose …
the development of tissue equivalent dosimeters able to render three-dimensional dose …