Experimentally testing the role of blood vessels in the full scattering profile: solid phantom measurements

I Feder, H Duadi, M Fridman, T Dreifuss… - Journal of Biomedical …, 2016 - cyberleninka.ru
Optical methods for biomedical purposes mostly use reflected light, while few of them use
the transmitted light. The blood vessels pose a challenge to these methods due to their high …

Detecting Contaminants in Water Based on Full Scattering Profiles within the Single Scattering Regime

A Tzroya, S Erblich, H Duadi, D Fixler - ACS omega, 2023 - ACS Publications
Clean water is essential for maintaining human health. To ensure clean water, it is important
to use sensitive detection methods that can identify contaminants in real time. Most …

Narrowband diffuse reflectance spectroscopy in the 900–1000 nm wavelength region to quantify water and lipid content of turbid media

JH Lam, KJ Tu, S Kim - Biomedical Optics Express, 2021 - opg.optica.org
We report a narrow wavelength band diffuse reflectance spectroscopy (nb-DRS) method to
determine water and fat ratios of scattering media in the 900–1000 nm range. This method …

Porous phantoms mimicking tissues—investigation of optical parameters stability over time

P Listewnik, M Ronowska, M Wąsowicz, VV Tuchin… - Materials, 2021 - mdpi.com
Optical phantoms are used to validate optical measurement methods. The stability of their
optical parameters over time allows them to be used and stored over long-term periods …

Near‐infrared human finger measurements based on self‐calibration point: Simulation and in vivo experiments

H Duadi, I Feder, D Fixler - Journal of biophotonics, 2018 - Wiley Online Library
Near‐infrared light allows measuring tissue oxygenation. These measurements relay on
oxygenation‐dependent absorption spectral changes. However, the tissue scattering, which …

Optical Method for Detection and Classification of Heavy Metal Contaminants in Water Using Iso-pathlength Point Characterization

A Tzroya, H Duadi, D Fixler - ACS omega, 2024 - ACS Publications
Water pollution caused by hazardous substances, particularly heavy metal (HM) ions, poses
a threat to human health and the environment. Traditional methods for measuring HM in …

A Self-Calibrated Single Wavelength Biosensor for Measuring Oxygen Saturation

M Katan, O Pearl, A Tzroya, H Duadi, D Fixler - Biosensors, 2024 - mdpi.com
Traditional methods for measuring blood oxygen use multiple wavelengths, which produce
an intrinsic error due to ratiometric measurements. These methods assume that the …

Effect of Spatial Modulated Light on Position of Self-Calibration Point

I Feder, H Duadi, D Fixler - IEEE Photonics Journal, 2021 - ieeexplore.ieee.org
In optical sensing, the differentiation between absorption and scattering poses a challenge
when dealing with a physiological medium. We have shown that for extracting absorption …

Technical Validation of Photoacoustic Imaging Systems Using Phantoms

L Hacker, J Joseph - Biomedical Photoacoustics: Technology and …, 2024 - Springer
Technical validation studies are paramount for objective performance evaluation and
calibration of novel imaging devices, aiding their development and effective translation into …

A Measurement System for Quasi-Spectral Determination of Absorption and Scattering Parameters of Veterinary Tissue Phantoms

P Listewnik, M Wąsowicz, M Kosowska, A Mazikowski - Applied Sciences, 2019 - mdpi.com
Featured Application The paper presents a proposal of a measurement system for
determination of optical parameters of the phantoms imitating animal tissues. The system …