[HTML][HTML] Eulerian formulation of the tensor-based morphology equations for strain-based blood damage modeling

N Dirkes, F Key, M Behr - Computer Methods in Applied Mechanics and …, 2024 - Elsevier
The development of blood-handling medical devices, such as ventricular assist devices,
requires the analysis of their biocompatibility. Among other aspects, this includes hemolysis …

Resistance valves in circulatory loops have a significant impact on in vitro evaluation of blood damage caused by blood pumps: a computational study

P Wu, Y Bai, G Du, L Zhang, X Zhao - Frontiers in Physiology, 2023 - frontiersin.org
Background: Hemolysis and its complications are major concerns during the clinical
application of blood pumps. In-vitro circulatory testing loops have been employed as the key …

Effect of impeller rotational phase on the FDA blood pump velocity fields

K Ucak, F Karatas, K Pekkan - Artificial Organs, 2024 - Wiley Online Library
Abstract Background The Food and Drug Administration (FDA) blood pump is an open‐
source benchmark cardiovascular device introduced for validating computational and …

Computational fluid dynamics simulating of the FDA benchmark blood pump with different coefficient sets and scaler shear stress models used in the power-law …

A Onder, O Incebay, R Yapici - Journal of Artificial Organs, 2024 - Springer
Hemolysis is the most important issue to consider in the design and optimization of blood-
contacting devices. Although the use of Computational Fluid Dynamics (CFD) in hemolysis …

Blood trauma in veno-venous extracorporeal membrane oxygenation: low pump pressures and low circuit resistance matter

C Blum, M Landoll, SE Strassmann, U Steinseifer… - Critical Care, 2024 - Springer
Background Veno-venous extracorporeal membrane oxygenation (VV ECMO) has become
standard of care in patients with the most severe forms of acute respiratory distress …

Synchronous PIV measurements of a self-powered blood turbine and pump couple for right ventricle support

K Ucak, F Karatas, E Cetinkaya, K Pekkan - Scientific Reports, 2024 - nature.com
A blood turbine-pump system (iATVA), resembling a turbocharger was proposed as a
mechanical right-heart assist device without external drive power. In this study, the iATVA …

[HTML][HTML] Systematic analysis of non-intrusive polynomial chaos expansion to determine rotary blood pump performance over the entire operating range

C Blum, U Steinseifer, M Neidlin - Computers in Biology and Medicine, 2024 - Elsevier
This study applies non-intrusive polynomial chaos expansion (NIPCE) surrogate modeling
to analyze the performance of a rotary blood pump (RBP) across its operating range. We …

Incorporating Unresolved Stresses in Blood Damage Modeling: Energy Dissipation More Accurate Than Reynolds Stress Formulation

J Abeken, D de Zélicourt… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
Objective: Reynolds Averaged Navier Stokes (RANS) models are often used as the basis for
modeling blood damage in turbulent flows. To predict blood damage by turbulence stresses …

Towards Robust Hemolysis Modeling with Uncertainty Quantification: A Universal Approach to Address Experimental Variance

C Blum, U Steinseifer, M Neidlin - arXiv preprint arXiv:2407.18757, 2024 - arxiv.org
Purpose: The purpose of this study is to address the lack of uncertainty quantification in
numerical hemolysis models, which are critical for medical device evaluations. Specifically …

Robust shape optimization of the FDA blood pump

C Miccoli, B Collins, A Scardigli, F Gallizio - Meccanica, 2024 - Springer
In recent decades, significant effort has been put into designing ventricular assist devices to
treat heart conditions, as heart transplantation can benefit only a small number of patients …