EHRA expert consensus statement and practical guide on optimal implantation technique for conventional pacemakers and implantable cardioverter-defibrillators …

H Burri, C Starck, A Auricchio, M Biffi, M Burri… - EP …, 2021 - academic.oup.com
A thrombin-like serine protease, jararassin-I, was isolated from the venom of Bothrops
jararaca. The protein was obtained in high yield and purity by a single chromatographic step …

Chest wall and abdominal blocks for thoracic and abdominal surgeries: a review

R Sharma, J Damiano, I Al-Saidi… - Current Pain and …, 2023 - Springer
Abstract Purpose of Review The purpose of this review is to provide an up-to-date
description and overview of the rapidly growing literature pertaining to techniques and …

Ultrasound-guided access to the axillary vein for implantation of cardiac implantable electronic devices: a systematic review and meta-analysis

S D'Arrigo, F Perna, MG Annetta… - The Journal of …, 2023 - journals.sagepub.com
The aims of our systematic review were to quantify the expected rate of procedural success,
early and late complications during CIED implantation using US-guided puncture of the …

Translation of Tools and Techniques from the Adult Electrophysiology World to Pediatric Cardiac Implantable Electronic Devices

TS Howard, JM Vinocur - Cardiac Electrophysiology …, 2023 - cardiacep.theclinics.com
Self-contained, cardiac implantable electronic devices (CIEDs) were first used in humans
beginning in 1958 when Ake Senning implanted the first permanent pacemaker in a 40-year …

Efficacy and safety of supraclavicular and pectoralis nerve blocks as primary peri‐procedural analgesia for cardiac electronic device implantation: A pilot study

P Antiperovitch, AT Mokhtar, R Yee… - Pacing and Clinical …, 2023 - Wiley Online Library
Background Cardiac implantable electronic devices (CIEDs) are routinely implanted using
intravenous drugs for sedation. However, some patients are poor candidates for intravenous …

Body mass index is related to unsuccessful puncture attempts and failure to axillary vein cannulation during ultrasound-guided cardiac electronic device implantation

F De Sensi, L Addonisio, P Baratta, M Breschi… - Journal of Interventional …, 2021 - Springer
Purpose Ultrasound (US)-guided axillary vein cannulation is effective and safe during
cardiac implantable electronic devices (CIEDs). It is a reasonable alternative to other …

Ultrasound utilization for implantation of cardiac implantable electronic devices

M Mian, HR Khan - Wiener klinische Wochenschrift, 2023 - Springer
Ultrasound (US) guidance for implantation of cardiac implantable electronic devices (CIED)
is currently not routine practice. This article sought to review published data on the use of …

A Novel Nerve Block Technique for a Patient Undergoing Cardiac Device Implantation

P Antiperovitch, AT Mokhtar, M Mian, R Yee, HR Khan - Case Reports, 2022 - jacc.org
A woman with type 1 myotonic dystrophy received an implantable cardioverter-defibrillator
using a novel combination of ultrasound-guided supraclavicular nerve and pectoral nerve …

Ultrasound guided Interpectoral, Pectoserratus and Serratus anterior plane blocks

G Armissoglio, P Serchan, L Griseto… - Medical …, 2023 - medultrason.ro
Abstract Interpectoral, Pectoserratus and Serratus anterior plane blocks are relatively recent
fascial plane blocks performed with ultrasound guidance to provide analgesia of the anterior …

Модифицированные блокады надключичного и грудных нервов при имплантации внутривенной порт-системы у онкологических пациентов

МП Яковенко, ЭЭ Антипин… - Общая …, 2023 - reanimatology.com
Модифицированные блокады надключичного и грудных нервов при имплант Page 1 28
www.reanimatology.com GENERAL REANIMATOLOGY, 2023, 19; 3 https://doi.org/10.15360/1813-9779-2023-3-28-38 …