Numerical models for lateral behaviour analysis of cold-formed steel framed walls: State of the art, evaluation and challenges
Cold-formed steel (CFS) shear walls are the primary lateral load resisting components in
lightweight steel framed (LSF) structures. The development of increasing complex LSF …
lightweight steel framed (LSF) structures. The development of increasing complex LSF …
Lateral force resisting systems in lightweight steel frames: Recent research advances
Abstract Lightweight Steel Frames (LSF) made by framing thin gauge cold-formed steel
(CFS) into different structural elements such as walls, trusses and joists are commonplace in …
(CFS) into different structural elements such as walls, trusses and joists are commonplace in …
[HTML][HTML] Modeling stiffness of connections and non-structural elements for dynamic response of taller glulam timber frame buildings
Currently, there is limited knowledge of the dynamic response of taller glue laminated
(glulam) timber buildings due to ambient vibrations. Based on previous studies, glulam …
(glulam) timber buildings due to ambient vibrations. Based on previous studies, glulam …
Experimental investigation of post-fire mechanical properties of cold-formed steels
S Gunalan, M Mahendran - Thin-Walled Structures, 2014 - Elsevier
Cold-formed steel members are widely used in residential, industrial and commercial
buildings as primary load-bearing elements. During fire events, they will be exposed to …
buildings as primary load-bearing elements. During fire events, they will be exposed to …
Experimental and numerical study of the seismic behavior of cold-formed steel walls with diagonal braces
Y Shi, X Ran, W Xiao, K Ke, Y Xiang, R Deng - Thin-Walled Structures, 2021 - Elsevier
In this paper, the seismic performance of cold-formed thin-walled steel walls with diagonal
braces is studied by means of experiments and finite element analysis. In total, horizontal …
braces is studied by means of experiments and finite element analysis. In total, horizontal …
Behavior of cold-formed steel wall stud with sheathing subjected to compression
J Ye, R Feng, W Chen, W Liu - Journal of Constructional Steel Research, 2016 - Elsevier
A detailed experimental investigation of the axial performance of sixteen full-scale cold-
formed steel (CFS) walls is presented. The impact of various parameters, such as sheathing …
formed steel (CFS) walls is presented. The impact of various parameters, such as sheathing …
Finite element modelling of load bearing cold-formed steel wall systems under fire conditions
S Gunalan, M Mahendran - Engineering Structures, 2013 - Elsevier
Abstract Light Gauge Steel Framing (LSF) walls are made of cold-formed, thin-walled steel
lipped channel studs with plasterboard linings on both sides. However, these thin-walled …
lipped channel studs with plasterboard linings on both sides. However, these thin-walled …
Seismic response of CFS shear walls sheathed with nailed gypsum panels: Numerical modelling
Building codes around the globe are in a transition to update their design guidelines to meet
the objectives of performance based seismic design (PBSD). The fulfilment of the objectives …
the objectives of performance based seismic design (PBSD). The fulfilment of the objectives …
Lightweight steel framed systems in seismic areas: Current achievements and future challenges
R Landolfo - Thin-Walled Structures, 2019 - Elsevier
Lightweight steel framed systems (LWS) are innovative construction systems whose
application has been steadily increasing over the years thanks to the huge benefits in terms …
application has been steadily increasing over the years thanks to the huge benefits in terms …
Design of built-up back-to-back CFS channel compression members sheathed with gypsum plasterboards
ST Vy, M Mahendran - Journal of Constructional Steel Research, 2022 - Elsevier
Built-up back-to-back cold-formed steel channel (BC) members are increasingly used as
studs for increasing the compression capacity of light gauge steel framed (LSF) walls, even …
studs for increasing the compression capacity of light gauge steel framed (LSF) walls, even …